AT-560
[RE5F22A]
DTC P0765 SHIFT SOLENOID VALVE D
Revision: November 2006
2006 Altima
2.
CHECK SHIFT SOLENOID VALVE D CIRCUIT
1.
Turn ignition switch “OFF”.
2.
Disconnect the TCM connector.
3.
Check resistance between TCM connector terminal 26 and
ground.
OK or NG
OK
>> GO TO 7.
NG
>> GO TO 3.
3.
CHECK TERMINAL CORD ASSEMBLY WITH SHIFT SOLENOID VALVE D
1.
Turn ignition switch “OFF”.
2.
Disconnect terminal cord assembly harness connector.
3.
Check resistance between terminal 1 and ground.
OK or NG
OK
>> GO TO 4.
NG
>> GO TO 5.
4.
CHECK HARNESS BETWEEN TCM AND TERMINAL CORD ASSEMBLY
Check the following.
●
Open or short-circuit in the harness between TCM and terminal cord assembly.
OK or NG
OK
>> GO TO 7.
NG
>> Repair or replace damaged parts.
5.
CHECK SHIFT SOLENOID VALVE D
1.
Remove side cover. Refer to
2.
Disconnect shift solenoid valve D harness connector.
3.
Check resistance between terminal 1 and ground.
OK or NG
OK
>> GO TO 6.
NG
>> Replace the control valve assembly. Refer to
Connector
Terminal
Condition
Resistance
(Approx.)
F57
26 - Ground
Temperature: 20
°
C (68
°
F)
11 - 16
Ω
SCIA2890E
Connector
Terminal
Condition
Resistance (Approx.)
F30
1 - Ground
Temperature: 20
°
C (68
°
F)
11 - 16
Ω
WCIA0453E
Connector
Terminal
Condition
Resistance (Approx.)
F103
1 - Ground
Temperature: 20
°
C (68
°
F)
11 - 16
Ω
SCIA4339E