AT-588
[RE5F22A]
DTC P0826 MANUAL MODE SWITCH CIRCUIT
Revision: November 2006
2006 Altima
TCM terminals and data are reference value. Measured between each terminal and ground.
Terminal
Wire
color
Item
Condition
Data (Approx.)
5
L/Y
Manual mode
switch UP (+)
Selector lever: + side
0V
Other than the above
Battery voltage
6
L/R
Manual mode
switch DOWN (-)
Selector lever: - side
0V
Other than the above
Battery voltage
16
SB
Manual mode
switch AUTO
Selector lever: “P”, “R”, “N” or “D” position
0V
Selector lever: Manual shift gate position
Battery voltage
19
P/B
Manual mode
switch MANUAL
Selector lever: Manual shift gate position (neutral)
0V
Other than the above
Battery voltage