AT-704
[RE5F22A]
SERVICE DATA AND SPECIFICATIONS (SDS)
Revision: November 2006
2006 Altima
Line Pressure
ECS009JY
Time Lag
ECS009JZ
Shift Solenoid Valves
ECS009K0
*: Except when automated up/down shift control and up/down shift permission control are actuated. Refer to
.
Solenoid Valves
ECS009K1
Specified resistance at 20
°
C (68
°
F).
Engine speed
Line pressure
kPa (kg/cm
2
, psi)
D, M positions
R position
At idle speed
333 - 392 (3.4 - 4.0, 48 - 57)
500 - 608 (5.1 - 6.2, 73 - 88)
At stall speed
1,285 - 1,393 (13.1 - 14.2, 186 - 202)
1,706 - 1,981 (17.4 - 20.2, 247 - 287)
Selector lever
Time
N to D position
Less than 0.7 sec.
N to R position
Less than 1.2 sec.
Shift position
Shift solenoid valve
Remarks
A
B
C
D
E
P
OFF (Open)
OFF (Closed)
OFF (Closed)
OFF (Open)
OFF (Closed)
PARK POSITION
R
OFF (Open)
OFF (Closed)
ON (Open)
OFF (Open)
ON (Open)
REVERSE POSITION
N
OFF (Open)
OFF (Closed)
OFF (Closed)
OFF (Open)
OFF (Closed)
NEUTRAL POSITION
D
1st
ON (Closed)
ON (Open)
ON (Open)
OFF (Open)
OFF (Closed)
Automatic shift
1
⇔
2
⇔
3
⇔
4
⇔
5
1
⇔
2
OFF (Open)
OFF (Closed)
ON (Open)
OFF (Open)
OFF (Closed)
2nd
OFF (Open)
OFF (Closed)
ON (Open)
OFF (Open)
OFF (Closed)
2
⇔
3
OFF (Open)
OFF (Closed)
ON (Open)
ON (Closed)
ON (Open)
3rd
OFF (Open)
OFF (Closed)
ON (Open)
ON (Closed)
OFF (Closed)
3
⇔
4
OFF (Open)
OFF (Closed)
OFF (Closed)
ON (Closed)
ON (Open)
4th
OFF (Open)
OFF (Closed)
OFF (Closed)
ON (Closed)
OFF (Closed)
4
⇔
5
OFF (Open)
ON (Open)
OFF (Closed)
ON (Closed)
OFF (Closed)
5th
OFF (Open)
ON (Open)
OFF (Closed)
ON (Closed)
OFF (Closed)
M5
5th
OFF (Open)
ON (Open)
OFF (Closed)
ON (Closed)
OFF (Closed)
Locks in 5th gear*
M4
4th
OFF (Open)
OFF (Closed)
OFF (Closed)
ON (Closed)
OFF (Closed)
Locks in 4th gear*
M3
3rd
OFF (Open)
OFF (Closed)
ON (Open)
ON (Closed)
OFF (Closed)
Locks in 3rd gear*
M2
2nd
OFF (Open)
OFF (Closed)
ON (Open)
OFF (Open)
OFF (Closed)
Locks in 2nd gear*
M1
1st
ON (Closed)
ON (Open)
ON (Open)
OFF (Open)
ON (Open)
Locks in 1st gear*
Solenoid valves
Resistance (Approx.)
Connector (Color)
Terminal
Shift solenoid valve A
11 - 16
Ω
(B)
1 - Ground
Shift solenoid valve B
(GY)
1 - Ground
Shift solenoid valve C
(GY)
1 - Ground
Shift solenoid valve D
(L)
1 - Ground
Shift solenoid valve E
(G)
1 - Ground
Pressure control solenoid valve A
5.0 - 5.6
Ω
(G)
1 - 2
Pressure control solenoid valve B
(B)
1 - 2
Pressure control solenoid valve C
(L)
1 - 2