AT-708
[RE5F22A]
SERVICE DATA AND SPECIFICATIONS (SDS)
Revision: November 2006
2006 Altima
A/T Fluid Temperature Sensor
ECS009K4
Turbine Revolution Sensor
ECS009K5
*: Voltage with both end of 100
Ω
resistance.
Revolution Sensor
ECS009K6
*: Voltage with both end of 100
Ω
resistance.
Condition
Voltage (Approx.)
Resistance (Approx.)
ATF temperature
0
°
C (32
°
F)
4.0V
9.8 k
Ω
20
°
C (68
°
F)
3.0V
4.2 k
Ω
80
°
C (176
°
F)
0.8V
0.54 k
Ω
100
°
C (212
°
F)
0.5V
0.31 k
Ω
Condition
Signal
Voltage* (Approx.)
Connect 12V power supply and 100
Ω
resistance, and then shake magnetic body.
HIGH
1.2 - 1.6V
LOW
0.4 - 0.8V
Condition
Signal
Voltage* (Approx.)
Connect 12V power supply and 100
Ω
resistance, and then shake magnetic body.
HIGH
1.2 - 1.6V
LOW
0.4 - 0.8V