DTC P0765 SHIFT SOLENOID VALVE D
AT-561
[RE5F22A]
D
E
F
G
H
I
J
K
L
M
A
B
AT
Revision: November 2006
2006 Altima
6.
CHECK HARNESS BETWEEN TERMINAL CORD ASSEMBLY AND SHIFT SOLENOID VALVE D
Check the following.
●
Open or short-circuit in the harness between terminal cord assembly and shift solenoid valve D.
OK or NG
OK
>> GO TO 7.
NG
>> Repair or replace transmission wire. Refer to
AT-629, "Terminal Cord Assembly"
7.
CHECK DTC
Perform “DTC Confirmation Procedure”. Refer to
AT-557, "DTC Confirmation Procedure"
OK or NG
OK
>> INSPECTION END
NG
>> GO TO 8.
8.
CHECK TCM
1.
Check TCM input/output signal. Refer to
AT-459, "TCM Input/Output Signal Reference Values"
2.
If NG, recheck TCM pin terminals for damage or loose connection with harness connector.
OK or NG
OK
>> INSPECTION END
NG
>> Repair or replace damaged parts.
Component Inspection
ECS009H0
SHIFT SOLENOID VALVE D
1.
2.
Disconnect shift solenoid valve D harness connector.
3.
Check resistance between terminal 1 and ground.
4.
If NG, replace the control valve assembly. Refer to
Connector
Terminal
Condition
Resistance (Approx.)
F103
1 - Ground
Temperature: 20
°
C (68
°
F)
11 - 16
Ω
SCIA4339E