www.javad.com
Prego Operator’s Manual
3
-
7
S E T U P A N D M E A S U R I N G
Measuring with the Prego
code and carrier phase measurement corrections, providing much greater
accuracy than single-frequency receivers over long baselines or during
ionospheric storms. Secondly, dual frequency receivers need far less
observation time to reach the desired accuracy requirement.
After the measuring completes, data the receivers collect can be
downloaded onto a computer and processed using post-processing software
(for example, Ensemble).
The procedure that follows describes the steps the operator should take to
perform a static measuring using MinPad.
1. Connect your receiver and computer. See “Connecting the Prego and a
Computer” on page 2-4 for this procedure.
2. Using PCView, click
Configuration->Receiver
->MinPad
and specify the following parameters, or specify parameters
according to your particular job, then click
Apply
• Recording Interval – 15 seconds
• Elevation Mask Angle – 15 degrees
• File Name Prefix – last 3 digits of receiver serial number
• LED blink mode switch – enable to start and stop static data recording
using the FN key.
Figure 3-3. Configuration->Receiver->MinPad
3. Click
Advanced
and then the
Multipath
tab and set the following
parameters, then click
Apply
• Code Multipath Reduction – enable
Summary of Contents for Prego
Page 2: ......
Page 8: ...VI Prego Operator s Manual www javad com Notes ...
Page 20: ...XVIII Prego Operator s Manual www javad com Notes ...
Page 92: ...3 22 Prego Operator s Manual www javad com Notes ...
Page 118: ...4 26 Prego Operator s Manual www javad com Notes ...
Page 140: ...B 14 Prego Operator s Manual www javad com Notes ...
Page 144: ...C 4 Prego Operator s Manual www javad com Notes ...
Page 148: ...E 2 Prego Operator s Manual www javad com Notes ...