background image

6                                                                                                                                                                                                

www.javad.com

In most cases, power supply with 12 VDC, 1 Amp sta-

bilized output will be good enough for Evaluation Kit 

powering.

Serial RS-232 connection

A standard Null-Modem cable (not included in the Kit) 

with DE-9 Female connectors on both ends and with 

length from 1 to 10 meters may be used to connect PC 

COM_X port with Serial A, Serial B or Serial C port, D 

port on Evaluation Kit as well as to provide connection 

between two Evaluation Kits to send some data from 

one OEM receiver to another OEM receiver.
DE-9 Female connector external view and pinout is 

shown on the picture below.

Figure 2. 

DE-9 Female connector

The Serial RS-232 Null-Modem cable should be wired 

according to the wiring table below:

Table: 1. 

Serial RS-232 Null-Modem cable wiring table

DE-9 Female, 

side 1

Cable Wiring

DE-9 Female, side 2

Signal 

Name Pin Wire Number Pin

Signal Name

CD

1

1

CD

RXD

2

Wire 1

3

TXD

TXD

3

Wire 2

2

RXD

DTR

4

6

DSR

GND

5

Wire 3

5

GND

DSR

6

4

DTR

RTS

7

Wire 4

8

CTS

CTS

8

Wire 5

7

RTS

RI

9

9

RI

Shield

shell  Drain 

Wire

shell

Shield

The Serial RS-232 Null-Modem cable should be wired 

according to the wiring table below.

Table: 2. 

Serial RS-232 Straight Through cable wiring 

table

DE-9 Female, 

side 1

Cable Wiring

DE-9 Female, side 2

Signal 

Name Pin Wire Number Pin

Signal Name

CD

1

1

CD

RXD

2

Wire 1

2

RXD

TXD

3

Wire 2

3

TXD

DTR

4

4

DTR

GND

5

Wire 3

5

GND

DSR

6

6

DSR

RTS

7

Wire 4

7

RTS

CTS

8

Wire 5

8

CTS

RI

9

9

RI

Shield

shell  Drain 

Wire

shell

Shield

Serial RS-422 connection

Serial RS-422 port may be used to connect OEM receiv-

er with other external devices as well as connect two 

OEM receivers together for some data exchange be-

tween them.
A Null-Modem RS-422 cable (not included in the Kit) 

with DE-9 Female connectors on both ends and with 

length from 1 to 100 meters may be used to connect 

two OEM receivers together. The DE-9 Female connec-

tor external view and pinout shown in Figure 2-4.
For best results, we recommend to use high quality STP 

5 or 5e category cable type as well as specialized for 

RS-422 applications cable types, for example: Belden 

9730, 9830 or similar.
The Serial RS-422 Null-Modem cable should be wired 

according to the wiring table below.

Table: 3. 

Serial RS-422 Null-Modem cable wiring table

DE-9 Female, 

side 1

Cable Wiring

DE-9 Female, side 2

Signal 

Name

Pin

Pair Number: Wire 

Number

Pin Signal Name

GND

5

Pair 1: Wire 1

5

GND

2

2

3

3

TXD+

7

Pair 2: Wire 1

8

RXD+

TXD-

3

Pair 2: Wire 2

2

RXD-

6

6

7

7

Summary of Contents for TRE

Page 1: ...served The information contained herein may not be used accessed copied stored displayed sold modified published or distributed or otherwise reproduced without express written consent from JAVAD GNSS TRE Evaluation Кit Application Notes Version 1 0 Last Revised May 7 2021 ...

Page 2: ... JAVAD GNSS Inc 2021 www javad com ...

Page 3: ...ICULAR USE OR PURPOSE JAVAD GNSS AND ITS DISTRIBUTORS SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING PERFORMANCE OR USE OF THESE MATERIAL OR THE TRE EVALUATION KIT SUCH DISCLAIMED DAMAGES INCLUDE BUT ARE NOTLIMITEDTOLOSSOFTIME LOSSORDESTRUCTION OF DATA LOSS OF PROFIT SAVINGS OR REVENUE OR LOSS OF THE PRODUCT S USE IN ADDITION JAVAD GNSS IS NOT RESPONSIBLE...

Page 4: ...e centers Users should review and heed the safety warnings in Appendix A MISCELLANEOUS The above Terms and Conditions may be amended modified superseded or canceled at any time by JAVAD GNSS The above Terms and Conditions will be governed by and construed in ac cordance with the laws of the State of California with out reference to conflict of laws WEEE Directive The following information is for E...

Page 5: ... antenna using TNC to MMCX RA Antenna cable 14 574101 03 included in the Kit and one of our external GNSS Antenna Cables purchased separately Accessory GPS Antenna Cable 3m RG 58 14 578107 01 Accessory GPS Antenna Cable 10m RG 58 14 578107 02 Power connection The OEM board powered through Evaluation Kit and Power Cable 14 508021 01 included in Kit The Banana plugs of power cable may be connected t...

Page 6: ...ing table below Table 2 Serial RS 232 Straight Through cable wiring table DE 9 Female side 1 Cable Wiring DE 9 Female side 2 Signal Name Pin Wire Number Pin Signal Name CD 1 1 CD RXD 2 Wire 1 2 RXD TXD 3 Wire 2 3 TXD DTR 4 4 DTR GND 5 Wire 3 5 GND DSR 6 6 DSR RTS 7 Wire 4 7 RTS CTS 8 Wire 5 8 CTS RI 9 9 RI Shield shell Shield Drain Wire shell Shield Serial RS 422 connection Serial RS 422 port may ...

Page 7: ...valuation Kit board For best results we recommend to use as short as pos sible from0 5to3meters USBhighqualitycableswith marking similar to this USB SHIELDED 28AWG 1P 24AWG 2C HIGH SPEED USB 2 0 USB connection can not be used to connect two OEM receivers together di rectly for data exchange This is because OEM receiver has device type of USB port that may be connected only to host type of USB port...

Page 8: ...set pos mode cur pd For OEM receiver Ethernet port connection with LAN the Straight Through Patch Cord cable usually used Straight Through cable should be wired according to the wiring table below Table 6 Ethernet Straight Through cable wiring table RJ45 Male side 1 Cable Wiring RJ45 Male side 2 Signal Name Pin Pair Number Wire Colour Pin Signal Name TX BI_DA 1 Pair 2 White Orange 1 TX BI_DA TX BI...

Page 9: ...sistors on both ends This may be achieved by jumpers at J126 for CAN A and J127 for CAN B ports on Evaluation Kit board Additionally CAN ports messages identifiers should be configured in both OEM receivers so each receiver will accept messages transmitted only by its partner Example Two receivers connected together through their CAN A ports Receiver 1 settings set dev can a sid in first 0x710 set...

Page 10: ... If you have difficulty inserting the plug turn it over and reinsert it If the unit will not the used for a long time disconnect the plug from the outlet Note Before plugging the power cord into an AC outlet make sure that all the connections have been made CAUTION To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you a...

Page 11: ...erwise treated without care erroneous measurements may occur Inform JAVAD GNSS immediately if this prod uct does not function properly Only allow authorized JAVAD GNSS warranty service centers to service or re pair this product Note Do not connect or disconnect equipment with wet hands you are at risk of electric shock if you do ...