background image

www.javad.com

  

7

DE-9 Female, 

side 1

Cable Wiring

DE-9 Female, side 2

Signal 

Name

Pin

Pair Number: Wire 

Number

Pin Signal Name

RXD+

8

Pair 3: Wire 1

7

TXD+

RXD-

2

Pair 3: Wire 2

3

TXD-

shell

Drain Wire

shell

In some cases, to connect other external devices with 

Evaluation Kit RS-422 port, not Null-modem, but 

Straight Through RS-422 cable may be used. 
The Serial RS-422 Straight Through cable should be 

wired according to the wiring table below.

Table: 4. 

Serial RS-422 Straight Through cable wiring 

table

DE-9 Female, 

side 1

Cable Wiring

DE-9 Female, side 2

Signal 

Name Pin

Wire Number

Pin

Signal Name

GND

5

Pair 1: Wire 1

5

GND

2

2

3

3

TXD+

7

Pair 2: Wire 1

8

RXD+

TXD-

3

Pair 2: Wire 2

2

RXD-

6

6

7

7

RXD+

8

Pair 3: Wire 1

7

TXD+

RXD-

2

Pair 3: Wire 2

2

TXD-

shell  Drain Wire shell

USB connection

Evaluation Kit USB port may be used to connect OEM 

receiver with PC USB port. 
A standard USB 2.0 High Speed cable with USB type A 

Male connector on one side and USB type B Male con-

nector on other side (not included in the Kit) may be 

used to connect OEM receiver with PC through J116 

USB type B Female connector on Evaluation Kit board. 
A standard USB 2.0 High Speed cable with USB type A 

Male connector on one side and USB type Mini-B Male 

connector on other side (not included in the Kit) may 

be used to connect OEM receiver with PC through J115 

USB type Mini-AB Female connector on Evaluation Kit 

board. 
For best results, we recommend to use as short as pos-

sible (from 0.5 to 3 meters) USB high quality cables with 

marking similar to this: “USB SHIELDED 28AWG/1P + 

24AWG/2C HIGH-SPEED USB 2.0”. USB connection can-

not be used to connect two OEM receivers together di-

rectly for data exchange. This is because OEM receiver 

has “device” type of USB port, that may be connected 

only to “host” type of USB port, usually present on PC 

or on USB hubs.

Warning: 

Because both J116 USB type B and J115 USB type Mini-

AB Female connectors are physically connected to one and the 

same USB port, only one USB cable at a time may be used. Do not 

connect to Evaluation Kit two USB cables simultaneously.

Ethernet connection

The J119 “ETHERNET” port may be used to:
- connect OEM receiver with Local Area Network (LAN);
- connect OEM receiver with PC directly;
- connect two OEM receivers together directly.
For Ethernet connection we recommend to use short 

(from 1 to 10 meters) high quality UTP 5 or 5e category 

cable with two RJ45 Male connectors on both ends.
RJ45 Male connector external view and pinout shown 

below:

Figure 5. 

RJ45 Male connector

For direct connection between two OEM receivers 

or between one OEM receiver and PC, the Ethernet 

Crossover cable usually used. Crossover cable should 

be wired according to the wiring table below 

Table: 5. 

Ethernet Crossover cable wiring table.

RJ45 Male, 

side 1

Cable Wiring

RJ45 Male, side 2

Signal 

Name

Pin Pair Number: Wire 

Colour

Pin

Signal Name

TX+ (BI_DA+) 1 Pair 2: White/Orange 3

RX+ (BI_DB+)

TX- (BI_DA-)

2

Pair 2: Orange

6

RX- (BI_DB-)

RX+ (BI_DB+) 3

Pair 3: White/Green

1

TX+ (BI_DA+)

Summary of Contents for TRE

Page 1: ...served The information contained herein may not be used accessed copied stored displayed sold modified published or distributed or otherwise reproduced without express written consent from JAVAD GNSS TRE Evaluation Кit Application Notes Version 1 0 Last Revised May 7 2021 ...

Page 2: ... JAVAD GNSS Inc 2021 www javad com ...

Page 3: ...ICULAR USE OR PURPOSE JAVAD GNSS AND ITS DISTRIBUTORS SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING PERFORMANCE OR USE OF THESE MATERIAL OR THE TRE EVALUATION KIT SUCH DISCLAIMED DAMAGES INCLUDE BUT ARE NOTLIMITEDTOLOSSOFTIME LOSSORDESTRUCTION OF DATA LOSS OF PROFIT SAVINGS OR REVENUE OR LOSS OF THE PRODUCT S USE IN ADDITION JAVAD GNSS IS NOT RESPONSIBLE...

Page 4: ...e centers Users should review and heed the safety warnings in Appendix A MISCELLANEOUS The above Terms and Conditions may be amended modified superseded or canceled at any time by JAVAD GNSS The above Terms and Conditions will be governed by and construed in ac cordance with the laws of the State of California with out reference to conflict of laws WEEE Directive The following information is for E...

Page 5: ... antenna using TNC to MMCX RA Antenna cable 14 574101 03 included in the Kit and one of our external GNSS Antenna Cables purchased separately Accessory GPS Antenna Cable 3m RG 58 14 578107 01 Accessory GPS Antenna Cable 10m RG 58 14 578107 02 Power connection The OEM board powered through Evaluation Kit and Power Cable 14 508021 01 included in Kit The Banana plugs of power cable may be connected t...

Page 6: ...ing table below Table 2 Serial RS 232 Straight Through cable wiring table DE 9 Female side 1 Cable Wiring DE 9 Female side 2 Signal Name Pin Wire Number Pin Signal Name CD 1 1 CD RXD 2 Wire 1 2 RXD TXD 3 Wire 2 3 TXD DTR 4 4 DTR GND 5 Wire 3 5 GND DSR 6 6 DSR RTS 7 Wire 4 7 RTS CTS 8 Wire 5 8 CTS RI 9 9 RI Shield shell Shield Drain Wire shell Shield Serial RS 422 connection Serial RS 422 port may ...

Page 7: ...valuation Kit board For best results we recommend to use as short as pos sible from0 5to3meters USBhighqualitycableswith marking similar to this USB SHIELDED 28AWG 1P 24AWG 2C HIGH SPEED USB 2 0 USB connection can not be used to connect two OEM receivers together di rectly for data exchange This is because OEM receiver has device type of USB port that may be connected only to host type of USB port...

Page 8: ...set pos mode cur pd For OEM receiver Ethernet port connection with LAN the Straight Through Patch Cord cable usually used Straight Through cable should be wired according to the wiring table below Table 6 Ethernet Straight Through cable wiring table RJ45 Male side 1 Cable Wiring RJ45 Male side 2 Signal Name Pin Pair Number Wire Colour Pin Signal Name TX BI_DA 1 Pair 2 White Orange 1 TX BI_DA TX BI...

Page 9: ...sistors on both ends This may be achieved by jumpers at J126 for CAN A and J127 for CAN B ports on Evaluation Kit board Additionally CAN ports messages identifiers should be configured in both OEM receivers so each receiver will accept messages transmitted only by its partner Example Two receivers connected together through their CAN A ports Receiver 1 settings set dev can a sid in first 0x710 set...

Page 10: ... If you have difficulty inserting the plug turn it over and reinsert it If the unit will not the used for a long time disconnect the plug from the outlet Note Before plugging the power cord into an AC outlet make sure that all the connections have been made CAUTION To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you a...

Page 11: ...erwise treated without care erroneous measurements may occur Inform JAVAD GNSS immediately if this prod uct does not function properly Only allow authorized JAVAD GNSS warranty service centers to service or re pair this product Note Do not connect or disconnect equipment with wet hands you are at risk of electric shock if you do ...

Page 12: ...900 Rock Avenue San Jose CA 95131 USA Phone 1 408 770 1770 Fax 1 408 770 1799 www javad com All rights reserved JAVAD GNSS Inc 2021 ...

Reviews: