________________________________________________________________________________________________________________________________________________________________
CN3600 Setup & Operation Manual Revision : 6/2020
59
6.4 FAULT SCREEN/ERROR CODES (
Electrical/Pneumatic
)
(M1001)Main Mandrel AC Drive-OL
➢
Check Mandrel VSD display
➢
Cycle Power
➢
Call Electrician
(M1002)Knife AC Drive-OL
➢
Check Knife Rotate VSD
➢
Cycle Power
➢
Call Electrician
(M1003)No1.Servo Drive traverse-OL
➢
Check Traverse Servo-controller two digit display
–
Call Electrician
(M1004)No2.Servo Drive (Knife in/out)-OL
➢
Check Knife IN/OUT Servo-controller two digit display
–
Call Electrician
(M1005)Main Mandrel motor CB-OL
➢
Reset
(M1006)Knife Motor CB-OL Tripped
➢
Reset
(M1007)No1 Traverse Servo CB-OL Tripped
➢
Reset
(M1008)No2.Knife Servo CB-OL Tripped
➢
Reset
(M1009)No1 sharpen motor-OL
➢
Reset
(M1010)No2.Sharpen motor CB-OL
➢
Reset
(M1011)Sharpener Time Error
(M1012)Sharpener Time Error
(M1013)"Sharpener Unlock" Error
(M1015)Knife Pivot Servo-OL
GLOSSARY:
Cycle Machine
:
means switch off power at switch on front panel, wait 30 seconds and restart
–
if this
does not rectify problem
–
switch off power at main isolator switch on electrical cabinet, wait 60 seconds
and switch back on and restart machine.
Pendant:
Hand Held Module;
OPR:
Operator Position Reset;
CB
:
Circuit Breaker;
OL:
Overload;
Servo:
Servo Motor Controller (Amplifier);
Limit:
Limit Switches
VSD:
Variable Speed Drive (Invertor);
E/Stop
: Emergency Stop; Door: Guards
REFER FIG 6.4 ON PAGE 68 FOR LOCATIONS IN ELECTRICAL CABINET
IMPORTANT NOTE TO ALL OPERTORS
Ensure you record the fault code on screen every time
BEFORE
attempting to
remedy any problem. These fault codes can expedite resolution to any problems if
an Electrician needs to be called in.