7.12- Clearing the OREV transmitter parameters
This procedure returns the
OREV
transmitter to its « factory »
con
fi
guration (default con
fi
guration on delivery), with the following
settings :
• Identity code group N°1,
• Radio transmit power level 4,
• «Normal» operating mode,
• Radio channel N°17,
• «Standby» time delay period of 4min.
The procedure for clearing the parameters of the
OREV
transmitter is performed using internal button
S1
of the
transmitter.
1
Open the housing of the
OREV
transmitter.
2
Press and hold button
S1
for around 10 seconds.
The
Va
and
Vb
indicator lights of the transmitter
fl
ash alternately.
Clearing and re-programming of the « factory » parameters of the transmitter is
completed when the
Va
and
Vb
indicator lights go off.
3
Close the housing of the
OREV
transmitter.