- 73 -
Orion
- 324501G
DE
FR
EN
6.3- Orion receivers (ORR)
Rail DIN
(
ORRD
)
Industrial
(small model)
(
ORRS
)
Industrial
(large model)
(
ORRA
)
Housing material
PC-GF
ABS
ABS
Housing color
Grey
Yellow
Grey
Tightness
IP20
IP65
IP65
Maximum weight
220 g.
350 g.
1200 g.
Number of command outputs
3 or 2+1 (1)
2 or 4+1 (1)
8+1 (1) or 16+1 (1)
Power supply
12 VDC (-25%/+25%)
24 VDC (-10%/+30%)
24 VAC (+10%/-15%)
ORRS••••F model
12 VDC (9 to 20VDC)
24 VDC (20 to 75VDC)
24 VAC (+10%/-15%)
48 VAC (+10%/-15%)
ORRS••••T model
115 VAC (+10%/-15%)
ORRS••••U model
230 VAC (+10%/-15%)
ORRA••••4 model
12 VDC (9 to 20VDC)
24 VDC (20 to 28VDC)
ORRA••••A model
24 VAC (+10%/-15%)
48 VAC (+10%/-15%)
ORRA••••B model
115 VAC (+10%/-15%)
230 VAC (+10%/-15%)
Max. consumption
75 mA for DC
3,5 VA for AC
180 mA for DC
5 VA for AC
260 mA for DC
11 VA for AC
Min. consumption
320mW for 12/24 VDC
23 mA for 12VDC
350mW for 24VDC
23 mA for 12VDC
350mW for 24VDC
Mounting
Snap-on fastener on
symetrical DIN rail EN
50 022
2 holes M4 exterior
4 holes M4 interior
Cable entry
/
1 or 2 plastic cable glands
(depend on model):
PG 13,5 (ø 8 to 12 mm)
1 plastic cap :
PG M16 (ø 5 to 7 mm)
1 plastic cable gland :
PG M32 (ø 20 to 26 mm)
Connection to equipment
Junction blocks (for cable 2,5 mm2)
« Power supply » indicator light
1 green indicator light
1 green indicator light
1 green indicator light
« Radio reception » indicator light
1 yellow indicator light
1 green indicator light
1 green indicator light
« Programming » indicator light
1 red indicator light
1 red indicator light
1 red indicator light
« Relay activated » indicator light
no indication
1 red indic. light per relay
1 red indic. light per relay
Antenna
External by BNC plug
1/4 wave
fi
xed antenna (2) or internal (3)
Tuner, Sensitivity
UHF 433,100 MHz to 434,740 MHz, < 2
μ
V
Operating temperature range
- 20°C to + 50°C
Storage temperature range
- 30°C to + 70°C
Identity code
256 identity codes possible, programmable by teaching on associated transmitter.
With maximum per relay of : :
- 10 identi
fi
cation codes for different transmitters on Rail DIN (
ORRD
) and industrial «small
model» receivers (
ORRS
)
- 4 identi
fi
cation codes for different transmitters on industrial «large model» (
ORRA
) receivers
Output command type
by relay with 1 NO contact
(1 NC contact or 1 bistable contact possible by programming)
Output response time
50 ms
Operating mode
Continuous or bistable (by programming jumper or microswitch)
Interlocking
Programmable by jumper or microswitch
Additional function
1 «
RM
» relay (depending on receiver model) Cat. B safety stop according to EN954-1
if controlled by transmitter «
On/Off
» button
(1) =
«
RM
» relay
(2) =
Plug-in feature possible by BNC plug on industrial receivers, with kit ref :
OWR01
(see installation in
appendix E
).
(3) =
Antenna integration possible in industrial receiver housings, with kit ref : OWR02 (delivered with the
receivers). Beware, the range is divided by 2 in this case. (see installation in
appendix F
).
Summary of Contents for Orion
Page 2: ... 2 Orion 324501G ...
Page 30: ... 30 Orion 324501G FR DE EN ...
Page 56: ... 56 Orion 324501G ...
Page 84: ... 84 Orion 324501G FR DE EN ...
Page 110: ... 110 Orion 324501G ...
Page 138: ... 138 Orion 324501G FR DE EN ...
Page 164: ... 164 Orion 324501G ...