- 58 -
UR
- 323245J
FR
EN
DE
4.1.6- "Dead man" function
The "dead man" safety function deactivates the URE transmitter (radio transmission cut off) when the
pushbuttons (BPSV, BPDV and "On/Horn") have not been actuated for a duration of
N
minutes or
seconds.
The
N
parameter is user-configurable and can take the values
01
to
98
minutes or seconds.
In the standard configuration, the time unit is in minutes. On delivery, the duration is defined for 4
minutes.
The temporization unit can be modified by following the procedure described in §6.3.3
- If the time unit is in
minutes
and the
N
value configured is
99 minutes
, the transmitter considers
that the dead man duration is infinite (until the battery is entirely discharged).
- If the time unit is in
seconds
and the
N
value configured is
99 seconds
, the transmitter will be
deactivated after 99 seconds if no action has been performed on the transmitter.
Restarting the transmitter after the "Dead man" function has been activated:
- Press the stop palmswitch button on the transmitter.
- Unlock the stop palmswitch button on the transmitter.
- Press the green "On/Horn" button (If option "starting up by IR validation" chosen, the operator has to
aim at the infrared UDF module).
Changing the dead man duration or temporization unit :
The dead man duration or unit
N
can be modified by a trained operator by performing the procedure
described in § 6.3.3.
NB :
Rotary switches
COM2
,
COM3
, and
COM3R
do not act on the "Dead man" function The
manipulation of these types of buttons does not rearm the temporization).
If the operator has to use switches during a long period, the temporization must be lengthened
or removed by programming, or the operator will have to rearm the temporization by pressing
regularly on the "On/Horn" button or another pushbutton type.
Summary of Contents for UR Series
Page 2: ... 2 UR 323245J ...
Page 3: ...UR 323245J 3 FR EN DE Radiocommande Série UR Notice technique d installation et d utilisation ...
Page 42: ... 42 UR 323245J FR EN DE ...
Page 82: ... 82 UR 323245J FR EN DE ...
Page 83: ...UR 323245J 83 FR EN DE Funkfernsteuerung Serie UR Technische Notiz und Benutzerhandbuch ...
Page 122: ... 122 UR 323245J FR EN DE ...
Page 123: ...UR 323245J 123 FR EN DE Annexes Appendix Anhang ...
Page 136: ... 136 UR 323245J ...
Page 137: ...UR 323245J 137 NOTES ...
Page 138: ... 138 UR 323245J NOTES ...
Page 139: ...UR 323245J 139 ...