200W

0.00Ω

0.00V

---F

VW Mode

200W

0.00Ω

0.00V

450F

TC Mode

Wattage Regulation in TC/VW Mode:

In TC/VW mode, output wattage can be adjusted from 1W to 200W. In unlocked 

mode, press the up button to increase the wattage and press the down button to 

decrease the wattage.

TC Mode:

Temperature Setting: In locked mode, press the up and down buttons 

simultaneously until the temperature setting is enlarged. Press the up button to 

increase the temperature and press the down button to decrease the 

temperature.

 

Note: 

In TC mode, be careful to attach new atomizers that have cooled to room 

temperature. If a new atomizer has not cooled down before attaching, the 

temperature may read and protect incorrectly until the new atomizer cools.

When you connect a new atomizer or disconnect and reconnect your existing 

atomizer, the device will prompt you to confirm this change and a message will 

prompt “New Coil? UP YES/DOWN NO”. Press the up button to confirm that a 

new atomizer has been attached. Press the down button to confirm that the 

same atomizer has been reconnected.

CHECK

ATOMIZER

Indication and Protection

Check Atomizer: 

The device does not detect an atomizer, 

the atomizer has shorted out, or the atomizer resistance is 

incorrect for the power setting. 

Shorted: 

Check all connections.  

Weak Battery: 

The battery needs to be charged, or a higher rate battery 

needs to be used. If this happens, the Reuleaux will continue to fire the 

atomizer, but will not be able to provide the desired wattage. The Weak Battery 

message will continue to flash for a few seconds after the end of puff. 

Temperature Protected:

 The heating coil reached the maximum allowed 

temperature during the puff. If this happens, the Reuleaux will continue to fire, 

but will not be able to provide the desired wattage. 

Ohms Too High:

 The resistance of the atomizer coil is too high for the current 

wattage setting. If this happens, the Reuleaux will continue to fire, but will not be 

able to provide the desired wattage. The Ohms Too High message will continue 

to flash for a few seconds after the end of puff. 

Ohms Too Low:

 The resistance of the atomizer coil is too low for the current 

wattage setting. If this happens, the Reuleaux will continue to fire, but will not be 

able to provide the desired wattage. The Ohms Too Low message will continue 

to flash for a few seconds after the end of puff. 

Too Hot: 

The Reuleaux has onboard temperature sensing. It will shut down 

and display this message if the internal board temperature becomes excessive. 

Shift Between TC/VW Mode:

In locked mode, press the up and down buttons simultaneously until the 

temperature setting is enlarged. Keep pressing the up button until the sign “OFF” 

shows, tap the fire button and you enter the VW mode. In the same way, press 

the down button to enter the TC mode. 