Section 2: Occupant Safety
30
1.
Operate the RESET/SILENCE button.
2.
Call your emergency services (fire department or 911).
3.
Immediately move to fresh air (outdoors or by an open door or window).
4.
Do not re-enter the premises or move away from the open door or window until the
emergency service responders have arrived, the premises have been aired out, and your
alarm remains in its normal condition.
If your alarm reactivates within a 24 hour period, repeat steps 1-4 and call a qualified appli
-
ance technician to investigate for sources of carbon monoxide from fuel burning equipment
and appliances, and inspect for proper operation of this equipment. Make sure that motor
vehicle(s) are not, and have not been, operating in an attached garage or adjacent to the
recreation vehicle.
If problems are identified during this inspection, have the alarm serviced immediately. Note
any combustion equipment not inspected by the technician and consult the manufacturer’s
instructions or contact the manufacturer directly for more information about carbon monox-
ide safety and this alarm.
Alarm signals
Normal operation:
The LED will maintain a steady green light, indicating that
the alarm is powered.
CO alarm condition:
The red LED light will remain steady and the alarm will
sound 4 “BEEPS” then silent for 5 seconds. These signals indicate immediate
action is required.
Propane gas alarm:
The red LED flash and the alarm will sound a steady tone.
These signals indicate immediate action is required.
Alarm malfunction/low battery:
The gas LED will remain off and the Opera
-
tional/CO LED will alternate red/green and the alarm will sound once every 15
seconds.
End of life alarm:
The LED will flash red/red, green/green and the alarm will
“BEEP” every 25-30 seconds. The alarm should be immediately replaced.
Maintenance
Vacuum the alarm cover at least once a year. Clean the cover by hand using a cloth damp-
ened in clean water. Dry with a soft cloth. Do not spray the front panel of the alarm with
cleaning agents or waxes. This action may damage the sensor causing an alarm or cause the
alarm to malfunction. Do not paint the face of the alarm.
Testing the combination carbon monoxide/propane alarm
The TEST/RESET button tests all ELECTRICAL functions of the alarm. The TEST/Mute
switch is located on the front of the alarm. Press and hold the test button for 1 second. The
alarm is working properly if the GREEN indicator light changes color to RED and the horn
beeps 4 times. The Gas LED should also blink red.
Test the alarm operation after the RV has been in storage, before each trip and
at least once per week during use.
Summary of Contents for Eagle TT 2020
Page 1: ...Owner s Manual 0283661 2020 2020 TT and HT Towables...
Page 2: ......
Page 4: ......
Page 12: ...10...
Page 26: ...Section 1 Warranty Service 24 Notes...
Page 44: ...Section 3 Pre Travel Information 42 Notes...
Page 72: ...Section 4 Vehicle Operation 70 Notes...
Page 118: ...Section 7 Fuel Propane System 116 Notes...
Page 176: ...Section 11 Electronics 174 Notes...
Page 186: ...Section 12 Interior 184 Notes...
Page 196: ...Section 14 Travel Camping Storage Checklists 194 Notes...