119
Section 8: Plumbing System
5. Close all faucets including outside shower. Turn pump
OFF.
6.
Drain the system again, but do not drain the water heater
(Water heater power still OFF).
7.
Close low point drains and fresh water tank drain.
8. Refill the fresh water tank with clean potable water. Use
the city water fill connection inlet, and one of the two methods explained in Step 3.
9.
Open faucets and check that the chlorine taste is gone.
10. Drain the system one more time.
11. Remove the clear tube and replace the cartridge filter (if so equipped), or remove full
system canister, insert filter, and reattach canister to the mount.
12. Refill the fresh water system with clean water.
After filling the water tank, set the valves to either
DRY CAMPING
or
CITY WATER
in order for water to flow through all fixtures in the plumbing system. Water heater
power can be restored. (Storage type water heater
must
be full of water)
WINTERIZING THE PLUMBING SYSTEM:
Preparing your recreation vehicle for colder weather or storage is very important for most
states and Canada. Failure to prepare your RV may cause water supply lines and the water
heater to freeze. The RV should be winterized at the end of the camping season or when it
will be exposed to temperatures that will fall at or below 32°F (0°C). Repairs due to freezing
are not covered by warranty.
If you chose to perform the winterization process yourself, read and understand the following
information before starting. Contact customer service or your dealer for questions about this
process. Refer to the
P3 Uni-Dock Utility System
section for valve settings. It may be easier
to winterize the RV with another person to assist you.
NOTE:
The winterization process may vary slightly due to different
plumbing configurations between models.
NOTE:
Appliances (refrigerator, dishwasher or clothes
washer) must be winterized. Refer to the appliance
owner's manual for additional information or contact your
Dealer or Customer Service for assistance.
NOTE:
The water heater must be drained to prevent dam-
age from freezing.
The valves on the P3 utility center automati
-
cally bypass the water heater.
Do not drain the water heater
while it is hot or under pressure! Antifreeze should be kept
out of the water heater.
Table of Contents
Maintenance Record
Summary of Contents for Precept 2018
Page 2: ......
Page 4: ......
Page 10: ......
Page 12: ...10 Table of Contents Maintenance Record ...
Page 38: ...36 Section 2 Occupant Safety Notes Table of Contents Maintenance Record ...
Page 44: ...42 Section 3 Pre travel information Notes Table of Contents Maintenance Record ...
Page 164: ...162 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record ...
Page 168: ...166 Section 15 Additional Information Notes Table of Contents Maintenance Record ...