71
Section 5: Slideout Systems
8.
Pull the motor up until it disengages (about 1/2 inch).
9.
Repeat this process for both sides of the slide room.
10. Physically push/ pull the room back into the opening; keep both sides relatively even.
11. The room must be travel locked to keep the room in place for road travel.
Error Codes
When an error code occurs during operation, the board LEDs lights will indicate where the
problem is. For motor specific faults the green LED will blink (1) time for motor #1 and (2)
times for motor #2. The red LED will blink 2 to 9 times depending on the error code. Error
codes are as follows:
2 times
Battery capacity is low
enough to drop below 6 volts while running.
3 times
Battery (low) voltage
is below 8 volts at the start of a cycle.
4 times
Battery (high) voltage
is greater than 18 volts.
5 times
Excessive motor current
(high amperage) also indicated by (1) side of the slide
continually stalling.
6 times
Motor short circuit:
motor or wiring to motor has shorted out.
8 times
Hall signal not present
: encoder not providing a signal; usually a wiring problem.
9 times
Hall power short to ground:
power to encoder has been shorted to ground;
usually a wiring problem.
The board will need to be reset after an error code. Energizing the extend / retract switch
will reset the board; energizing it a second time will return it to normal operation.
Refer to the Schwintek Slide Room Operation Guide for additional troubleshooting
information, or contact Lippert at (866) 524–7821 or at www.lci1.com.
Norco Slideout System
The Norco slideout system is a cable driven slide out used typically on towable products.
The cables guide the room in or out, while the Accu-Slide mechanism evenly powers
the corners keeping the room square.
Motors and cables are behind the interior fascia board around the slideout opening.
Cables may stretch over time. Average stretch will be approximately 1/8” but it will not
affect the function and does not require adjustment.
Slideout runs off of the DC power in the RV.
Rubber wipes prevent debris from entering the unit and actuation guides the bulb seals
to close tightly.
Self-locking motor freezes the room in any position of travel.
Slideout is supported by rollers or wear bars not the cables. Cables are used to keep the
slideout balanced on the rollers.
If the room will not activate,
generally there is no 12V power to the drive motor. The
motor is equipped with a hex drive override shaft.
This drive can be activated using an electric drill and the flexible shaft provided with each
DO NOT MOVE THE RV UNLESS THE MOTORS ARE PLUGGED IN
TO THE CONTROLLER AND THERE IS BATTERY POWER TO THE RV.
THIS SETS THE BRAKES ON THE SLIDEOUTS TO PREVENT THEM
FROM MOVING DURING TRANSIT.
Table of Contents
Maintenance Record
Summary of Contents for Precept 2018
Page 2: ......
Page 4: ......
Page 10: ......
Page 12: ...10 Table of Contents Maintenance Record ...
Page 38: ...36 Section 2 Occupant Safety Notes Table of Contents Maintenance Record ...
Page 44: ...42 Section 3 Pre travel information Notes Table of Contents Maintenance Record ...
Page 164: ...162 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record ...
Page 168: ...166 Section 15 Additional Information Notes Table of Contents Maintenance Record ...