Section 6: Electrical System
30-amp Power Cord
The 30-amp external utility power cord is commonly referred to as the “shore” power cord.
It is designed to mate and properly function with 30-amp “shore” power receptacles avail-
able at most campgrounds.
The shore power cord is designed to continuously carry the 30-amp current flow required to
power each leg of the electrical system. It also creates a critical ground connection between
the vehicle electrical system and the campground shore power receptacle.
Always test the external power source (i.e., the campsite power receptacle or electrical box)
with a ground monitor before connecting your power cord to it. If the ground monitor indi-
cates ‘reverse polarity’ or an ‘open ground’
DO NOT
connect the power cord.
Regularly inspect the shore power cord for cuts, cracks, worn insulation and other damage.
Have the power cord replaced immediately if problems exist.
Calculating 30-amp Electrical Load
When connecting appliances to the electrical system, 120-volt power usage is limited to a
total of 30-amps. Operating appliances collectively places an added load on your 120-volt
electrical system.
A circuit breaker “trip” may occur if you overload the recreation vehicle and/or campground
electrical system. The amperage rating of individual appliances can be calculated by divid-
ing appliance wattage consumed (normally listed on the appliance) by nominal design volt-
age (120 for a 120-volt appliance). For example: 1200 watts divided by 120-volts equals 10
amps.
Do not hook up the power cord to any receptacle until you have verified
proper polarity and grounding. Polarity indicators can be purchased in
most electrical and hardware stores.
Do not use any cheater plug, adapter or extension cord to reconfigure
incoming AC power or break the continuity of the circuit connected to
the grounding pin.
Do not connect the power cord into an outlet that is not grounded, or
adapt the power cord plug to connect it to a receptacle for which it is not
designed.
Do not remove the grounding pin to connect to a non-grounded recep-
tacle. Removal of the ground pin disables an important safety feature
designed to prevent shock and electrocution hazards.
Do not connect the power cord to an extension cord. Use of an improper
extension cord will cause overheating of the cord as well as potentially
causing premature failure of the AC equipment.
It is the responsibility of the owner of the electrical receptacle to ensure that the
receptacle is properly wired and grounded. Reverse polarity and/or improper
grounding of your recreation vehicle can cause personal injury or death.
Generator
Your motor home is equipped with a diesel powered generator. The generator produces
120/240-volt power compatible with the motor home electrical system. It can power the
entire motor home when 120/240-volt shore power is not available.
Table of Contents
Maintenance Record
Summary of Contents for REDHAWK 2023
Page 1: ...2023 OWNER S MANUAL A subsidiary of Thor Industries Inc REDHAWK REDHAWK SE...
Page 2: ......
Page 20: ...14 Section 1 Warranty Service Notes Table of Contents Maintenance Record...
Page 32: ...26 Section 3 Pre Travel Information Notes Table of Contents Maintenance Record...
Page 58: ...52 Section 5 Slideout Systems Notes Table of Contents Maintenance Record...
Page 74: ...68 Section 6 Electrical System Notes Table of Contents Maintenance Record...
Page 82: ...76 Section 7 Fuel Propane System Notes Table of Contents Maintenance Record...
Page 108: ...102 Section 8 Plumbing System Table of Contents Maintenance Record...
Page 116: ...110 Section 10 Appliances Notes Table of Contents Maintenance Record...
Page 118: ...112 Section 11 Electronics Notes Table of Contents Maintenance Record...
Page 132: ...126 Section 13 Exterior Notes Table of Contents Maintenance Record...
Page 136: ...130 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record...
Page 140: ...134 Section 15 Additional Information Notes Table of Contents Maintenance Record...