79
Section 8: Plumbing System
NOTE: Fresh water tank sizes vary by model. Contact your dealer or Cus-
tomer Service for your specific tank size.
How to Sanitize
1.
Turn water heater power OFF (both electric and LP gas on standard storage water
heater). Single switch is inside the RV for the tankless water heater.
2.
Level the recreational vehicle and drain the fresh water system. (see
Draining the Fresh
Water System
).
3.
Close the low point drain valves and the fresh water tank drain valve.
4.
Water filter preparation:
Full System Canister water filter (if so equipped):
Remove the canister, take
the filter out of the canister, then reattach the empty canister.
Bypass the cartridge water filter (if so equipped):
Use the clear plastic tube
(supplied with RV) to bypass the water filter.
5.
Connect a garden hose to the city water inlet (do not use your fresh water hose to sani-
tize the water lines or the tank).
6.
Set the colored coded valves to the SANITIZE setting:
White handle pointing right
Blue handle pointing down
Green handle pointing left
Red handle pointing up
The water heater is automatically bypassed on this setting.
7.
Place the other end of the hose in a container holding sanitizing solution.
8.
Turn the pump switch ON (red LED will light). The solution will be drawn into the
fresh water tank. Turn the pump OFF when solution has been drawn into the tank. To
aid in siphoning, set the container on a surface approximately (2) feet off the ground.
The drain valves must be turned OFF.
9.
Remove the chlorine container and finish filling the fresh water tank with clean (po
-
table) water until the tank is full. Keep the valves set on SANITIZE.
10. Fill the fresh water tank full of clean (potable) water. Use water either from a pressur-
ized source, or from a container. Tank level can be viewed on the monitor panel inside
the RV.
Filling from a pressurized source:
Set the valves to
the POWER FILL TANK setting. Connect a non-
toxic drinking hose to the city water fill inlet. Connect
the other end of the hose to the pressurized water
source. Turn on the water source and fill until is full
(
Do Not Overfill
). Disconnect the hose from the wa-
ter source first, then disconnect from the utility panel.
Syphon filling from a water container:
Set the
valves to the SANITIZE setting. Insert a hose into
the city water fill inlet, place other end of the hose in a
container of water. Turn pump ON to draw water into
the tank until tank (
Do Not Overfill
). Remove the
hose and the container. To aid in siphoning place the
container approximately (2) feet off the ground. The
drain valves must be closed.
11. Leave the hose attached to the city water connection inlet and place other end of hose
in a container of fresh water. Turn the pump ON. Fresh water will be siphoned into
the tank. Turn pump OFF when tank is full. Disconnect the hose from utility center.
Table of Contents
Summary of Contents for SENECA PRESTIGE 2023
Page 1: ...2023 OWNER S MANUAL A subsidiary of Thor Industries Inc SENECA PRESTIGE ...
Page 2: ......
Page 20: ...14 Section 1 Warranty Service Notes Table of Contents ...
Page 32: ...26 Section 3 Pre Travel Information Notes Table of Contents ...
Page 50: ...44 Section 4 Vehicle Operation Notes Table of Contents ...
Page 58: ...52 Section 5 Slideout Systems Notes Table of Contents ...
Page 76: ...70 Section 7 Fuel Propane System Notes Table of Contents ...
Page 104: ...98 Section 9 Heating Cooling Notes Table of Contents ...
Page 126: ...120 Section 13 Exterior Notes Table of Contents ...
Page 130: ...124 Section 14 Travel Camping Storage Checklists Notes Table of Contents ...
Page 134: ...128 Section 15 Additional Information Notes Table of Contents ...