Section 8: Plumbing System
Turn the
Electric Hot Water switch ON
. This activates the 120 Volt-AC electric heating
element and the indicator light located on the
switch. Allow 1-2 hours for the Aqua-Hot
System to reach operating temperature.
Zone Thermostat Operation
Interior Room Thermostat:
Adjust each interior room thermostat to the desired temper-
ature. Whenever an interior room thermostat “calls for heat,” the Aqua-Hot’s circulation
pump and interior heat exchanger fans will be activated. Aqua-Hot must be at operating
temperature in order for the zones to function.
Using the Domestic Hot Water System
When the Aqua-Hot is at operating temperature, the domestic water is automatically heated
as it is being used. The Aqua-Hot system is tankless and does not store any hot water, con-
tinuous hot water will be present from any faucet. The Diesel-Burner switch must be
ON
in order to obtain a continuous supply of hot water; activate the electric element switch for
maximum
hot water capacity.
NOTE: The Aqua-Hot’s “Domestic Water Priority System” disables the inte-
rior zone heating fans and the zone circulation pumps whenever domestic hot
water is being used on a continuous basis. Once the demand for continuous
hot water ceases, the Aqua-Hot will enable the fans and the pumps to operate
and provide heat to the heating system.
NOTE: Both the Diesel-Burner and the electric heating element are thermo-
statically controlled. Either, or both heating sources will automatically main-
tain the temperature of the antifreeze and water heating solution between
approximately 160°F and 190°F (±5).
To heat the motor home/domestic hot water, choose the desired heat source(s) and leave the
switch(s) (burner and/or
electric hot water) ON.
Electric Hot Water:
When connected to shore power or when using the generator, the
Aqua-Hot electric heating element has the ability to function in order to provide heat for the
boiler tank.
The electric heating element is a
secondary heat source
for heating both the interior and the
domestic hot water during low heating demand situations (moderate ambient temperatures
exist and/or when there is a low demand for domestic hot water).
Maintenance (Aqua-Hot)
Refer to the Aqua-Hot owner’s manual for detailed procedures, system requirements
and parts information prior to performing any maintenance to the Aqua-Hot system.
Monthly Maintenance
Check the Aqua-Hot’s antifreeze and water heating solution to ensure that it is at the proper
level. This can be accomplished by visually checking the coolant level in the Aqua-Hot’s ex-
pansion tank. The coolant level should be checked
only
when the Aqua-Hot is at maximum
operating temperature (i.e., immediately after the Diesel-Burner cycles OFF). When the
Aqua-Hot is at maximum operating temperature, the antifreeze and water heating solution
should be at the level marked “HOT” on the expansion tank.
When the Aqua-Hot is at maximum operating temperature, the coolant will be
very HOT! If Aqua-Hot’s heating system is accessed, scalding by hot vapor
or coolant could result! Before cleaning or servicing, disconnect all power
supplies!
Table of Contents
Summary of Contents for SENECA PRESTIGE 2023
Page 1: ...2023 OWNER S MANUAL A subsidiary of Thor Industries Inc SENECA PRESTIGE ...
Page 2: ......
Page 20: ...14 Section 1 Warranty Service Notes Table of Contents ...
Page 32: ...26 Section 3 Pre Travel Information Notes Table of Contents ...
Page 50: ...44 Section 4 Vehicle Operation Notes Table of Contents ...
Page 58: ...52 Section 5 Slideout Systems Notes Table of Contents ...
Page 76: ...70 Section 7 Fuel Propane System Notes Table of Contents ...
Page 104: ...98 Section 9 Heating Cooling Notes Table of Contents ...
Page 126: ...120 Section 13 Exterior Notes Table of Contents ...
Page 130: ...124 Section 14 Travel Camping Storage Checklists Notes Table of Contents ...
Page 134: ...128 Section 15 Additional Information Notes Table of Contents ...