Section 6: Electrical System
37
Connecting the Power Cord
Always test the external power source (i.e., the campsite power receptacle or electrical box)
with a ground monitor before connecting your power cord to it. If the ground monitor indi-
cates ‘reverse polarity’ or an ‘open ground’
DO NOT
connect the power cord.
To help prevent power surges from damaging the connected loads, please follow these in-
structions when hooking up to the external power source:
1.
Turn off the load center main 120-volt circuit breaker.
2.
Carefully extend the entire length of the power cord (approximately 25’-35’) from the
external power source to the RV.
3.
Plug the power cord into the receptacle. Be sure all the power cord prongs are properly
plugged into the receptacle.
4.
Return to your RV and turn on the load center main circuit breaker.
The shore power cord should be unplugged when the recreation vehicle is left
unattended.
Do not hook the power cord to any receptacle until you have verified
proper polarity and grounding.
DO NOT
plug the shore power cord into a campsite receptacle(s):
That has reverse polarity
That has non-functioning ground circuits
That shows outward signs of heat damage.
Doing so may result in property damage or serious injury. Plugging the shore
power cord into an incorrectly wired power source could damage the recre-
ation vehicle electrical system and result in severe or fatal injury. Damage or
injury resulting from connection to malfunctioning or improperly wired power
sources is not covered by your recreation vehicle warranty.
DO NOT
Do not use any cheater plug, adapter or extension cord to reconfigure
incoming AC power or break the continuity of the circuit connected to
the grounding pin.
Do not connect the power cord into an outlet that is not grounded, or
adapt the power cord plug to connect it to a receptacle for which it is not
designed.
Do not remove the grounding pin to connect to a non-grounded recep-
tacle. Removal of the ground pin disables an important safety feature
designed to prevent shock and electrocution hazards.
Do not connect the power cord to an extension cord. Use of an improper
extension cord will cause overheating of the cord as well as potentially
causing premature failure of the AC equipment.
The power cord must be fully extended when in use and not left coiled
in the electrical compartment or on the ground. A power cord left coiled
may potentially create enough heat to melt its protective casing.
It is the responsibility of the owner of the electrical receptacle to ensure that
the receptacle is properly wired and grounded.
Reverse polarity and/or im-
proper grounding of your RV can cause property damage or serious per-
sonal injury.
Table of Contents
Summary of Contents for SWIFT Ali 2023
Page 1: ...2023 OWNER S MANUAL A subsidiary of Thor Industries Inc TERRAIN...
Page 2: ......
Page 24: ...Section 2 Occupant Safety 19 Notes Table of Contents...
Page 30: ...Section 3 Pre Travel Information 25 Notes Table of Contents...
Page 50: ...Section 6 Electrical System 45 Notes Table of Contents...
Page 68: ...Section 8 Plumbing System 63 Notes Table of Contents...
Page 78: ...Section 12 Interior 73 Notes Table of Contents...
Page 84: ...Section 13 Exterior 79 Notes Table of Contents...
Page 88: ...Section 14 Travel Camping Storage Checklists 83 Notes Table of Contents...
Page 91: ...Section 15 Additional Information 86 Notes Table of Contents...