background image

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

5/53

LED JIVE

Sound Mode
The unit works to rhythm of the beat when used in standalone or master/slave mode

Press the MENU button until “

SOUn

” is shown on the display.

Press the ENTER button, the display starts blinking.

Use DOWN and UP button to select “yes” (sound mode on) or “no” (sound mode off).

Once the mode is selected, press the ENTER button save it.

To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.

Sound Sensitivity
Used to set the sensitivity of the internal microphone

Press the MENU button until “

SenS

” is shown on the display.

Press the ENTER button, the display starts blinking.

Use DOWN and UP button to select a value between “0” (very low sensitivity) and “100” (high sensitivity).

Once the mode is selected, press the ENTER button save it.

To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.

Blackout Mode
Blackout mode: when no DMX-signal is detected the unit goes in blackout waiting for a DMX-signal.
No blackout mode: when no DMX-signal is detected, the unit automatically switches to standalone.

Press the MENU button until “

bLMd

” is shown on the display.

Press the ENTER button, the display starts blinking.

Use DOWN and UP button to select “Yes” (blackout on) or “No” (blackout off) mode.

Once the mode is selected, press the ENTER button to save it.

To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.

Display on/off
Display on: display is always lit.
Display off: display is dark when not used.

Press the MENU button until the display shows “

Led

”.

Press the ENTER button, the display starts blinking.

Use DOWN and UP buttons to select “On” (display always lit) or “Off” (display dark when not used).

Once the mode is selected, press the ENTER button to save it.

To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.

Display Inversion
Display normal: display is readable when the unit is on the floor.
Display inversion: display is readable when the unit is mounted upside down.

Press the MENU button until

“dISP”

is shown on the display. (normal display)

Press the ENTER button to toggle between

(normal display) and

(display inversion).

If you want to go back to normal running mode: press the MENU button for about 2 seconds.

Test
Used to activate the internal “self-test” program which checks all possibilities of the unit.

Press the MENU button until the display shows “

teSt

”.

Press the ENTER button to start the internal self-test program.

To go back to the functions press the MENU button.

If you want to go back to normal running mode: press the MENU button for about 2 seconds.

Fixture Hours
Used to show the number of working hours of the unit.

Press the MENU button until the display shows “

FhrS

”.

Press the ENTER button to show the number of working hours in the display.

To go back to the functions press the MENU button.

If you want to go back to normal running mode: press the MENU button for about 2 seconds.

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

6/53

LED JIVE

Software version
Used to show the software version that is installed in the unit

Press the MENU button until the display shows “

ver

”.

Press the ENTER button to show the software version on the display.

To go back to the functions press the MENU button.

If you want to go back to normal running mode: press the MENU button for about 2 seconds.

Reset
Used to force a reset of the unit.

Press the MENU button until the display shows “

rSet

”.

Press the ENTER button to reset the unit.

OVERHEAD RIGGING

Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.

Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed

at least 50cm

from surrounding walls.

The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.

Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s
weight.

Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.

The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!

Don’t cover any ventilation openings as this may result in overheating.

The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.

ELECTRICAL INSTAL ADDRESSING

Important: The electrical installation should be carried out by qualified personal only,

Electrical installation for 1 standalone unit:

Just insert the mains cable. The unit starts working immediately in stand-alone mode.

Remark1:

You can connect a CA-8 or RF-8 remote controller to the unit if you want to have more control.

Refer to “how to operate the unit” to learn how to do this.

Remark2:

if there’s no output, please make sure to set the unit in master mode and set the blackout mode

to “NO” and Sound Mode to “On” (see previous chapter)

Electrical installation for two or more units in master/slave:

In this mode the units will show a synchronized show, working to the rhythm of the beat.

Summary of Contents for LED jive

Page 1: ...ruiksaanwijzing Bedienungsanleitung Manual de instrucciones EN FR NL DE ES Copyright 2011 by BEGLEC NV t Hofveld 2C B1702 Groot Bijgaarden Belgium Reproduction or publication of the content in any man...

Page 2: ...s normas vigentes no seu pa s WARNING DANGER never expose the lens to direct sunlight even for a short period This may damage the light effect or even cause fire ATTENTION DANGER n exposez jamais la l...

Page 3: ...or moisture To avoid condensation to be formed inside allow the unit to adapt to the surrounding temperatures when bringing it into a warm room after transport Condense sometimes prevents the unit fro...

Page 4: ...ON MANUAL JB SYSTEMS 4 53 LED JIVE DMX Address Used to set the starting address in a DMX setup Press the MENU button until Addr is shown on the display Press the ENTER button the display starts blinki...

Page 5: ...ours Used to show the number of working hours of the unit Press the MENU button until the display shows FhrS Press the ENTER button to show the number of working hours in the display To go back to the...

Page 6: ...STARTING ADDRESS Refer to the previous chapter DMX 512 address setting to learn how to set the starting address on this unit The starting address of each unit is very important Unfortunately it is imp...

Page 7: ...s visibly damaged due to cracks or deep scratches it must be replaced The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is detected In order...

Page 8: ...ne laissez l appareil s adapter la temp rature ambiante quand vous la mettez dans une pi ce chauff e apr s le transport La condensation emp che parfois l appareil de fonctionner plein rendement ou peu...

Page 9: ...EC pour l alimentation de l appareil suivant 13 Entr e secteur avec prise IEC et porte fusible int gr branchez le c ble secteur ici MENU PRINCIPAL Pour s lectionner l une des fonctions appuyez sur la...

Page 10: ...ourner au mode de fonctionnement normal Maintenez enfonc e la touche MENU pendant environ 2 secondes FRAN AIS MODE D EMPLOI JB SYSTEMS 16 53 LED JIVE Inversion de l affichage Affichage normal L cran e...

Page 11: ...l s par DMX Dans ce mode les Shows des unit s seront synchronis s fonctionnant au rythme de la musique mais vous pouvez toujours contr ler certaines fonctions sur le ma tre via un canal DMX Pour assu...

Page 12: ...ux probl mes de fonctionnement cessez d utiliser l appareil et contactez imm diatement votre revendeur Important Ne regardez jamais directement dans la source de lumi re N utilisez pas le jeu de lumi...

Page 13: ...iet bloot aan regen of vocht Om te voorkomen dat binnenin condensatie wordt gevormd laat het apparaat aan de omgevingstemperatuur aanpassen wanneer het na transport in een warme kamer wordt gebracht C...

Page 14: ...SINGANG Wordt gebruikt om een eenvoudige RF 8 NEDERLANDS GEBRUIKSAANWIJZING JB SYSTEMS 24 53 LED JIVE draadloze bediening aan te sluiten terwijl het apparaat in de stand alone of master slave modus wo...

Page 15: ...ge wijziging naar het hoofdmenu terug te gaan druk kort op de MENU knop Als u naar de normale bedrijfsmodus wilt terugkeren druk ongeveer 2 seconden lang op de MENU knop NEDERLANDS GEBRUIKSAANWIJZING...

Page 16: ...seerde show weergeven Koppel 2 tot maximaal 16 apparaten met goede kwaliteit gebalanceerde microfoonkabels aan elkaar Het eerste apparaat in de keten zal automatisch als de master fungeren de andere a...

Page 17: ...korten De oppervlaktetemperatuur van het apparaat kan tot 85 C oplopen Raak tijdens de werking de behuizing niet met de blote handen aan Blackout Blackout het apparaat Functie 1 Synchrone stroboscoop...

Page 18: ...reiche Lightshows DMX Controller 1 oder 5 Kan le Einzelbetrieb Musikgesteuert mit eingebautem Mikro Master Slave wunderbar synchronisierte Vorf hrungen im Standalone Modus DMX Master Slave Diese neue...

Page 19: ...stark sein kann dass f r Personen die Gefahr von Stromschl gen besteht Das Ausrufezeichen im Dreieck weist den Benutzer auf wichtige Bedienungs und Wartungshinweise in den Dokumenten hin die dem Ger...

Page 20: ...e Modus eingestellt ist speichern Sie diesen mit ENTER Bei kurzem Bet tigen der Taste MENU k nnen Sie zum Hauptmen zur ckzukehren ohne eine nderung vorzunehmen Zur R ckkehr in den normalen Betriebsmod...

Page 21: ...ch w hrend des Auf oder Abbaus und der Wartung keine unbefugten Personen unterhalb des Ger ts befinden Das Ger t nur an einem gut bel fteten Ort und entfernt von entflammbaren Materialien und oder Fl...

Page 22: ...kabelgebundene Fernsteuerung Verbinden Sie die Fernsteuerung mit den Buchseneingang des ersten Ger ts Master RF 8SET drahtlose Fernsteuerung Die drahtlose Fernsteuerung besteht aus 2 Teilen RF 8T Kle...

Page 23: ...Vermeidung von berhitzung m ssen die Ventilatoren sofern vorhanden und L ftungsschlitze monatlich gereinigt werden Das Ger teinnere mindestens einmal pro Jahr mit einem Staubsauger oder einer Luftd s...

Page 24: ...de algunos minutos Para evitar el riesgo de incendio o de choque el ctrico no exponga este electrodom stico a la lluvia ni a la humedad Para evitar que se forme condensaci n en el interior del equipo...

Page 25: ...controlador inal mbrico RF 8 mientras que la unidad se utiliza en modo aut nomo o en el modo maestro esclavo ESPA OL MANUAL DE INSTRUCCIONES JB SYSTEMS 46 53 LED JIVE 8 Micr fono interno Recibe el son...

Page 26: ...e al modo aut nomo Presione el bot n MENU hasta que se muestre en el visualizador bLMd Presione el bot n ENTER el visualizador comienza a parpadear Utilice los botones DOWN y UP para seleccionar Yes b...

Page 27: ...dad en el modo maestro y establezca el modo de apagado blackout en NO y el Modo de sonido Sound Mode en On consulte el cap tulo anterior Instalaci n el ctrica para dos o m s unidades en el modo maestr...

Page 28: ...ar las direcciones DMX INSTRUCCIONES DE FUNCIONAMIENTO Una vez conectado a la alimentaci n este dispositivo comienza a funcionar Los descansos regulares durante la operaci n son esenciales para maximi...

Page 29: ...UAL DE INSTRUCCIONES JB SYSTEMS 53 53 LED JIVE Esta informaci n est sujeta a cambios sin notificaci n previa Puede descargar la versi n m s reciente de este manual de usuario en nuestro sitio Web www...

Reviews: