Sound Mode
The unit works to rhythm of the beat when used in standalone or master/slave mode
Press the MENU button until “
SOUn
” is shown on the display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP button to select “yes” (sound mode on) or “no” (sound mode off).
Once the mode is selected, press the ENTER button save it.
To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Sound Sensitivity
Used to set the sensitivity of the internal microphone
Press the MENU button until “
SenS
” is shown on the display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP button to select a value between “0” (very low sensitivity) and “100” (high sensitivity).
Once the mode is selected, press the ENTER button save it.
To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Blackout Mode
Blackout mode: when no DMX-signal is detected the unit goes in blackout waiting for a DMX-signal.
No blackout mode: when no DMX-signal is detected, the unit automatically switches to standalone.
Press the MENU button until “
bLMd
” is shown on the display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP button to select “Yes” (blackout on) or “No” (blackout off) mode.
Once the mode is selected, press the ENTER button to save it.
To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Display on/off
Display on: display is always lit.
Display off: display is dark when not used.
Press the MENU button until the display shows “
Led
”.
Press the ENTER button, the display starts blinking.
Use DOWN and UP buttons to select “On” (display always lit) or “Off” (display dark when not used).
Once the mode is selected, press the ENTER button to save it.
To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Display Inversion
Display normal: display is readable when the unit is on the floor.
Display inversion: display is readable when the unit is mounted upside down.
Press the MENU button until
“dISP”
is shown on the display. (normal display)
Press the ENTER button to toggle between
(normal display) and
(display inversion).
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Test
Used to activate the internal “self-test” program which checks all possibilities of the unit.
Press the MENU button until the display shows “
teSt
”.
Press the ENTER button to start the internal self-test program.
To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Fixture Hours
Used to show the number of working hours of the unit.
Press the MENU button until the display shows “
FhrS
”.
Press the ENTER button to show the number of working hours in the display.
To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
ENGLISH
OPERATION MANUAL
JB SYSTEMS
®
6/53
LED JIVE
Software version
Used to show the software version that is installed in the unit
Press the MENU button until the display shows “
ver
”.
Press the ENTER button to show the software version on the display.
To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Reset
Used to force a reset of the unit.
Press the MENU button until the display shows “
rSet
”.
Press the ENTER button to reset the unit.
OVERHEAD RIGGING
Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed
at least 50cm
from surrounding walls.
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s
weight.
Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
Don’t cover any ventilation openings as this may result in overheating.
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
ELECTRICAL INSTAL ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
Electrical installation for 1 standalone unit:
Just insert the mains cable. The unit starts working immediately in stand-alone mode.
Remark1:
You can connect a CA-8 or RF-8 remote controller to the unit if you want to have more control.
Refer to “how to operate the unit” to learn how to do this.
Remark2:
if there’s no output, please make sure to set the unit in master mode and set the blackout mode
to “NO” and Sound Mode to “On” (see previous chapter)
Electrical installation for two or more units in master/slave:
In this mode the units will show a synchronized show, working to the rhythm of the beat.