ENGLISH
OPERATION MANUAL
JB SYSTEMS
®
7/43
SCENEMASTER
The display shows “MId” to indicate that the receive mode is active.
The Scenemaster does NOT send any MIDI-commands, it only listens to incomings MIDI-data.
Except for the BLACKOUT button (9) pressing buttons and moving faders has no effect.
Only the BLACKOUT-button (9) is still active:
Press the BLACKOUT-button shortly: DMX-output goes in blackout but scenes are still active.
Press the BLACKOUT-button for 2 seconds: all scenes are switched off. (in case something goes wrong
in the MIDI-communication)
MIDI COMMANDS
Switching scenes on/off:
0x9n kk 127
Fading scenes gradually:
0xBn kk vv (vv: 0-127)
Blackout function:
0x9n kk 127
Remark: “n” = MIDI channel.
kk
Function
Function explain
0-15
SCENE1-16
Turn on/off and fade in/out Scenes 1-16(UNIT 1)
16-31
SCENE17-32
Turn on/off and fade in/out Scenes 17-32 (UNIT 2)
32-47
SCENE33-48
Turn on/off and fade in/out Scenes 33-48 (UNIT 3)
48-63
SCENE49-64
Turn on/off and fade in/out Scenes 49-64 (UNIT 4)
……
……
……
125
MASTER
Master fader in/out (ALL UNITS)
126
BLACKOUT
Turn on/off Blackout (ALL UNITS)
……
……
……
HOW TO USE - AS MIDI-CONTROLLER
If needed, updating the firmware in the Scenemaster is easy, just follow these steps:
Surf to the Scenemaster product page on our website (www.jbsystems.be) to check if new firmware is
available in the download section.
Download the file and unzip it: now you have a file named “SCM-1.SUP”
Put this file in a directory on your PC.
Connect the Scenemaster to one of the USB-inputs of your PC.
Turn the power of the Scenemaster OFF.
Press the “FLASH-button of channel 16” and the “PROGRAM-button” (8) together while you switch the
Scenemaster back on, you will notice 2 things:
The display on the Scenemaster shows “USb”
A new window, with directory named “SCENEMASTER” opens on your PC-screen.
This “SCENEMASTER” directory contains a file named “SCM-1.SUP”:
First delete the current file from the “SCENEMASTER” directory.
Now copy the new “SCM-1.SUP” file (downloaded from our website) in the directory.
Use the power switch (14) to switch the Scenemaster off.
After 5 seconds turn the unit back on: at startup the display will show the new software version.
Important remark:
do NOT switch the Scenemaster off while no new file was copied to the
“SCENEMASTER” directory, this will make the Scenemaster inoperable.
ENGLISH
OPERATION MANUAL
JB SYSTEMS
®
8/43
SCENEMASTER
SPECIFICATIONS
Power Input:
DC 9V 300mA minimum.
AC/DC Power adapter:
AC 230V, 50Hz
9Vdc / 300mA (or more)
Preserved working status:
last working status, 5s before shutdown, is preserved.
DMX outputs:
3pin XLR
MIDI in/out:
USB-B (slave) connector
Size:
482 x 133 x 75 mm (see drawing)
Weight:
3,5 kg
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com