We appreciate the confidence you have placed in JBC in purchasing this
station. It is manufactured to the most stringent quality standards in order to
give you the best possible service. Before turning on your station, we recommend
you read these instructions carefully.
Ref. 2600000
Converter
Ref. 0731100
Console AC 2600
SPECIFICATIONS
The console
AC 2600
is designed to modify the
original regulation program parameters of any of
the Advanced stations. Use the console when the
tool that will be connected to the corresponding
station’s output, should perform under special
characteristics of operation. Examples of special
characteristics are fixed temperature, delay of
sleep time, etc.
ATENTION
The original parameters have been defined through
our field experience in soldering. Before changing
any parameter, we recommend to evaluate the
modification as it can both improve and adulterate
the operation of the station.
One of the basic characteristics that allows the
Advanced system to perform with an exceptional
tip-life in comparison with other stations, is the
use of the sleep-mode.
With this console you can modify the parameters
of the sleep-mode: the temperature and the delay
before entering in sleep-mode, or even switching
off the sleep-mode if required.
Monitor
Ref. 0731000
ENGLISH
With the "Temperature adjust" function one can
modify the temperature indicated by the dial of
the station with an offset of ±50°C mod.
When adjusting the temperature it is important
to be aware of the following:
"Sleep" function.
"Sleep" function.
"Sleep" function.
"Sleep" function.
"Sleep" function.
Reducing the "Sleep temperature" and the "Sleep
delay time" will extend the tip-life considerably,
up to 10% for every 5°C reduction.
In production lines where the rest times are
short, if both the "Sleep temperature" and the
"Sleep delay time" are increased the overall
soldering efficiency will increase, but tip-life will
be reduced in the same proportion.
The default "Sleep temperature" and "Sleep delay
time" for every type of handpiece have been set
to values based on experience and can always
be retrieved using the "Reset" function.
"Temperature adjust" function.
"Temperature adjust" function.
"Temperature adjust" function.
"Temperature adjust" function.
"Temperature adjust" function.
Every centigrade Celsius that is added to the
maximum temperature will decrease the tip-life
with 1%, what means that a maximum adjustment
of 50°C will lead to a 50% reduction in tip-life.