Fix temperature
.
This feature is used to fix the temperature.
Once the temperature has been fixed, you can
check the selected temperature in the station by
moving the selector dial, the green LED -READY-
will remain on while the dial is set at the locked
temperature.
If the dial is not set at the locked temperature,
the green LED -READY- will be blinking. The
further the dial will be set from the locked
temperature the slower the blinking pace will be.
Moving the temperature dial on a fixed station
will only influence the LED, the temperature
remains at the selected level.
The standard factory settings do not include a
fixed temperature.
The console’s display will show «NOT FIXED» to
indicate that the station’s temperature is not fixed.
Sleep delay time
.
It regulates the delay time of the intake into
sleep mode since the time that the soldering
iron is left in the stand.
The longer this time is, the greater oxidation of
the tinning on the tip will be which will lessen the
cartridge life span.
It is advisable to indicate a delay time only when
the using of the iron is intensive, for example in
production, so to avoid interruption «stop & go».
Selected original time 0 minutes.
ENGLISH
Depending on the age of
AD 2000
control unit,
you won’t be able to accede so that you cannot
modify certain parameter.
If control unit belongs to the first production
series, nothing won’t be showed on the console's
display.
The unit's components
Console
AC 2600
ref. 2600000 is composed
b y :
- Monitor
Ref. 0731000
- Converter
Ref. 0731100
- Instructions manual
Ref. 0735400
Converter
Console
AC 2600
can be directly connected to
stations
AD 2000
,
AD 2200
and
AD 2700
.
In
order to connect the console to stations
AD
4200
,
AD 4300
,
DI 3000
,
AR 5500
,
AR 5800
,
DS
5300
,
AM 6000
and
AM 6500
you should place
the converter Ref. 0731100 between the end of
the console’s cable and connector of the
station.
2
Max temperature
.
(Only for digital stations
till 400ºC or 750ºF).
It allows to change the maximum temperature
between 400ºC and 450ºC or 750ºF and 850ºF.
OPERATION
Once the console has been connected to the
control unit, it will automatically show in the
console’s display the following messages:
f this is not showing, it means that the control
unit is not ready to accept the console. That is
to say, the version is too old.
ALTER PARAMETERS
This function is used to alter the original
parameter which the control unit has been
configured with.
Tool selection
.
It oblies prompts you to select the tool which you
want to work with and for the one you want to
change the parameters.
Temperature unit
.
Selection of temperature units in Celsius grades -
°C- or Fahrenheit -°F-.
CONSOLE AC 2600
VERSION X.xx
XXXXXX STATION