10
ENGLISH
Sleep function
One of the Series Advanced features is that when
the handpiece is placed in the holder, the
temperature at the tip drops automatically to the
sleep temperature. This function is only possible
because of the quick response time which does
not make the user realise the temperature rise to
reach the selected temperature. Also by this, the
oxidation of the tinning of the tip is considerably
reduced and tip life is extended.
To indicate that the soldering iron is in sleep-mode,
the green led starts pulsing. These parameters can
be modified using the
Console AC 2600
Ref. 2600000.
In order to take advantage of the above
mentioned feature and as a security measure,
it is necessary to place the handpiece on stand
when the iron is not being used.
When connecting an old version solder stand, it may
happen that the sleep function does not work.
To resolve this problem, you should make a bridge
between pins number 3 and 5 from the aerial
connector of the cable of the stand, that plugs in
the station.
Aerial connector
Bridge between
pin number 3 & 5
OPERATION
LED lights
Red LED -ON-
when lit, it indicates that the station is
plugged in the mains.
Green LED -READY-
when lit, it indicates that the
system is ready and correctly set for working.
The green led light is on after a few seconds, is the
time needed to carry on the self-checking system.
The green light is pulsing when the soldering iron is
in sleep mode.
If the green led is not lit, the reason why, will be one
of the following:
1. The handpiece or the cartridge are not plugged
in.
2. T h e m a x i m u m a v a i l a b l e p o w e r h a s b e e n
exceeded for too long - e.g. in a very thick
soldering at the high repetition rates.
3. T h e h a n d p i e c e o r c a r t r i d g e h a s a s h o r t
circuit or an open circuit.
4. Any other trouble preventing the system from
working properly.
The green led goes off when the cartridge tip
touches the extractor and the station stops the
power supply.
The handpiece will reset itself automatically should
the cartridge short circuit or go open circuit.
Should the handpiece be subject to:
- An electrical surge or the cartridge has not been
fitted correctly.
Please turn the unit off and switch on again to
reset.
Only for users of AC 2600 console ref. 2600000.
If you lock the working temperature thanks to the
console, the green LED -READY- will remain on
while the dial is set at the locked temperature.
If the dial is not set at the locked temperature,
the green LED -READY- will be blinking. The
farther the dial will be set from the locked
temperature the slower the blinking pace will be.