5
1.
Loosen the cartridge screw to release it.
Place the new cartridge in the Auto-feed iron.
Alignment
Guide tube
Ref . 0002401 - Ø 0,9 - 1,1 mm
Changing cartridge
For a safe cartridge change, unplug the tool or turn the station off before following these guidelines:
2.
Align the tip of the cartridge with the solder Guide tube.
Important:
It is essential to insert the cartridge till the end for a good connection. Use the mark as
reference. Tighten the cartridge screw.
3.
You must leave
a gap of 8-10
mm
between the tip and the end of the Guide tube.
4.
Loosen the guide screw. Adjust the Guide tube and tighten the screw.
1
3
4
2
www.jbctools.com
8-10 mm
Summary of Contents for AL250-B
Page 1: ...Auto Feed Iron Ref AL250 B www jbctools com...
Page 2: ...2...