5
OPERATION
Description of controls
-
PEDAL:
Hot air is produced when it is held down.
Releasing it the heater is disconnected,
though the turbine continues to operate
until the air temperature falls below 212°F.
-
BUTTONS:
Activates or desactivates the hot-air flow. After
a function-time of two minutes the hot-air flow
switches automatically off.
The red light indicates, that the heating element
is functioning. A malfunction is indicated by
the pulsing of the red led.
On/off switch for the self-contained suction
pump.
The yellow light of the switch indicates that
the self-contained vacuum pump is activated.
- CONTROLS:
TEMPERATURE
Allows fixing the temperature of the heater
between 300 and 850°F. The selected
temperatures are reference values which may
change depending on the distance between
the heating element and the nozzle.
Allows fixing the temperature of the soldering
and desoldering iron between 200 and 700°C.
AIR FLOW
This enables the air flow to be set on a scale from
1 (corresponding to the lowest setting of 6 l/min)
to 10 (corresponding to the highest of 45 l/min).
- VACUUM SELECTOR:
Two vacuum inlets avalaible, being active the
one that coincides with the arrow.
HEAT
VACUUM
DESOLDERING PROCEDURE WITH THE
HEATER
We would also recommend the use of the nozzles
of larger diameter, reserving the smallest one
(diam. 4 mm) for desoldering small components
such as resistors, condensers and the like, bearing
in mind that with this small nozzle the concentration
of heat is greater and care must be taken to avoid
burning the printed circuit; we recommend keeping
below a temperature of 662 °F and air flow of 6.
Depending on the size of the integrated circuit to
be desoldered, you will have to use:
A) Pro tripod.
B) Extractor.
C) Tripod.
A) Pro tripod:
- Select protector and tripod size in function of
the IC to be desoldered and place it over the
component.
- Use the
VACUUM
button to start the pump
and then fit the tripod. Press the sucker down
until it sticks onto the component.