background image

Safety

- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.

- The power cord must be plugged into approved bases. Be sure that it is properly grounded
  before use. When unplugging it, hold the plug, not the wire.

- Do not work on electrically live parts.

- The tool should be placed in the stand when not in use in order to activate the sleep mode.
  The soldering tip, the metal part of the tool and the stand may still be hot even when the station
  is turned off. Handle with care, including when adjusting the stand position.

- Do not leave the appliance unattended when it is on.

- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.

- Avoid the contact of flux with skin or eyes to prevent irritation.

- Be careful with the fumes produced when soldering.

- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when
  working to avoid personal harm.

- Utmost care must be taken with liquid tin waste which can cause burns.

- This appliance can be used by children over the age of eight and also persons with reduced
  physical, sensory or mental capabilities or lack of experience provided that they have been given
  adequate supervision or instruction concerning use of the appliance and understand the hazards
  involved. Children must not play with the appliance.

- Maintenance must not be carried out by children unless supervised.

  It is imperative to follow safety guidelines to prevent electric  
  shock, injury, fire or explosion. 

9

40 mm

50 mm

60 mm

80 mm

100 mm

130 mm

130 mm

para manuales - color gris

200 mm

300 mm

Summary of Contents for AT-SB

Page 1: ...INSTRUCTION MANUAL ATS Stand for AT420 Adjustable Thermal Tweezers ...

Page 2: ...unit Manual 1 unit Ref 0028204 Stand Cable 1m 1 unit Ref 0024227 Sponge for Modular Tool Stands 1 unit Ref S7034 Brass Wool 1 unit Ref CL6210 The following items are included This manual corresponds to the following references AT SB Packing List 2 ...

Page 3: ...y To Tool Wiper for Modular Tool Stand Ref CL7899 Adjustable Cable Collector Ref CC1001 Quick Tip Changer Cartridge Storage Adjustable Tool Holder Brass Wool inside Sponge 3 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm ...

Page 4: ...e wiper offers different ways to clean the cartridge tips If desired use the included sponge Insert the cable into the cable collector clip Do not leave the cable longer than necessary to reach the work area freely The cable collector is flexible It accompanies and adapts to the movements during the soldering process 4 ...

Page 5: ...er offers different ways to clean the cartridge tips Wiper and Brass Wool Replacement Lift the wiper at its front edge The wiper and brass wool can easily be removed for cleaning or replacement when they are worn Remove the wiper by pulling it out Replace the brass wool with a new one when it is worn out Place the wiper back o replace them if desired 5 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm ...

Page 6: ...ers to remove them 2 Use the vertical grooves to position the cartridges and place the tweezers onto the cartridges Important It is essential to insert the cartridges as far as the mark for a proper connection 3 Positioning 4 Inserting Press the cartridges against the extractor and make sure that the cartridge are inserted up to the mark 1 2 6 ...

Page 7: ...s required 1 Then lock the catridge fixing screws 2 Once the alignment has been made it is imperative to fix the cartridges by tightening the fixing screws It takes a single turn of the screw to lock it in place The wheel allows the tips to be adjusted so that they are aligned when the tweezers are closed 1 6 Vertical Cartridge Alignment 2 Rear Wheel aligned 7 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm...

Page 8: ...lcohol can be used only when cleaning the metal parts Check periodically that the metal parts of the tool stand are clean so that the station can check the tool s status Periodically check all cables and tube connections Replace any defective or damaged parts Use original JBC spare parts only Repairs should only be performed by a JBC authorized technical service 8 ...

Page 9: ...ite Avoid the contact of flux with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age of eight and also persons with reduced p...

Page 10: ...Notes 10 ...

Page 11: ...Notes 11 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm ...

Page 12: ...the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased para manuales color gris 0028204 1221 ATS Stand for AT420 Adjustable Thermal Tweezers Ref AT SB Includes Sleep Mode and Hibernation Mode Net Weight 1544 g 3 40 lb Package Dimensions Weight 342...

Reviews: