background image

Tool

ON

MENU

28174

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

348ºC

5,7 W

80%

350ºC

Tool

ON

MENU

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

WORK

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

80%

JBC

210

350ºC

Tool

ON

MENU

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

348ºC

5,7 W

80%

350ºC

JBC#1

JBC#1

MENU

Tool1

2822

Tool ID

Hibernation delay

Temperature units

00:30

Maximum Temperature

400ºC

Sleep mode
Sleep temperature

150ºC

Working
Low battery
Power OFF

Charging
No cartridge

Tool Status

ºC

ºF

JBC

210

Lock Parameters

Locked

Unlocked

Return to Work

Tool1

Tool ID

28714

Hardware

Software

0028283

X886787

Update File

File

Hardware

Software

Select your Firmware

-
-

Update

MENU

JBC

210

Return to Work

JBC#1

Bi115

Bi210

User’s Manual

User’s Manual

Documents

MENU

JBC#1

JBC

210

Return to Work

2822

Work

Settings

Counters

Update

Documents

Light Theme

Dark Theme

Disconnect

JBC#1

OK

Update

Tool

ON

MENU

JBC#1

24 W 100%

18 W 100%

12 W 100%

6 W 100%

0 W 100%

10 seconds/div

V1.2

WORK

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

80%

JBC

210

350ºC

Tool1

Tool1

Tool1

Tool1

Tool2

Tool3

Tool

ON

MENU

24 W

18 W

12 W

6 W

0 W

10 seconds/div

V1.2

CHARGE

450 ºC

350 ºC

250 ºC

150 ºC

50 ºC

JBC

210

80%

350ºC

JBC#1

348ºC

6 W

10

10

Operation

The JBC Most Efficient Soldering System

This revolutionary technology is capable of recovering tip temperature extremely quickly. It allows 
the user to work at a lower temperature.

Work

Charging and Hibernation 

When the tool is lifted from the 
stand the tip will heat up to the 
selected temperature. 

When the tool is in the stand 
enters into Hibernation Mode 
and cools down to room 
temperature.
While the tool remains in the 
stand, it charges.

Hibernation

When the tool is outside of the 
stand and remains inactive (no 
movement), the tool enters 
Hibernation mode and cools 
down to room temperature.

To turn the tool on, put it back 
into the stand.

Note:

 When the tool is lifted from the stand the Soldering System acts as follows:

If the tool has been inactive 
for a longer period of time, it is 
turned off.

long time 

inactive

Turned Off

Turned On

Note:

 If desired, the tool can be switched off/on. Tab the Tool 

Power switch on the tablet screen (bottom right) to switch it off/on.

Tool Power Switch

6

Summary of Contents for B iRON 115T

Page 1: ...High Precision Battery Rework Station B iRON 115T INSTRUCTION MANUAL...

Page 2: ...230 V United Kingdom BI115THA 230 V China BI115TJA 100 V Japan Cable USB 1 unit Ref 0028092 B iRON Console 1 unit Ref 0030035 Console not included BI115TUQA 120 V N America Taiwan BI115TIQA 230 V Indi...

Page 3: ...sole Note For references without a console Bluetooth devices like a tablet or mobile phone can be connected Power Socket USB Connector USB Cable only for charging Stand for B115T High Precision B iRON...

Page 4: ...tool completely 30 min before using it for the first time The status indicator light indicates as follows the tool status 2 1 Status Indicator Light 1 Connection 2 Cartridge Insertion and Charging gr...

Page 5: ...ool1 Tool2 3 Switching on Console Device Select the tool from the detection list Turn on the console device and open the B iRON Application 4 Selecting Tool Console Work Screen Temperature and Power G...

Page 6: ...ing and Hibernation When the tool is lifted from the stand the tip will heat up to the selected temperature When the tool is in the stand enters into Hibernation Mode and cools down to room temperatur...

Page 7: ...and power graphics The automatic recording can be paused by tapping the screen in the graphic area The automatic recording stops also when the tool stops working While the automatic recording is stop...

Page 8: ...moving excess solder by gently tapping or wiping the cartridge tip If the tip is very dirty JBC recommends first cleaning it with the wiper to remove excess solder and then with the brass wool Brass W...

Page 9: ...nd that there is space for the wiper on the right Assemble the antisplash membrane in a vertical direction onto the stand Press the antisplash membrane down Make sure that the membrane is correctly in...

Page 10: ...artridge and gently push the tweezers down Place the tweezers with the cartridge in the slot so that its reference ring rests in the slot and gently press the cartridge into the tweezers Important Pus...

Page 11: ...ignment function Cartridge tips can be rotationally and vertically aligned Rotationally Tip Alignment Rotate the bushings slightly 1 to rotationally align the tips 2 Wheel for vertically tip aligntmen...

Page 12: ...0 JBC 210 350 C JBC OK Tool MENU JBC 10 seconds WORK 450 C 350 C 250 C 150 C 50 C 80 JBC 210 350 C Tool MENU 10 seconds CHARGE 450 C 350 C 250 C 150 C 50 C JBC 210 80 350 C JBC 348 C 6 W 80 80 M 450 C...

Page 13: ...0 C Tool1 Tool ID 28714 Hardware Software 0028283 X886787 MENU JBC 2 Return to Work 2822 Work Settings Counters Update Documents Light Theme Dark Theme Disconnect Update Tool ON V1 2 350 C Tool1 Tool1...

Page 14: ...check that the metal parts of the tool and stand are clean so that the charging works properly Maintain the tip surface clean and tinned before storage in order to avoid tip oxidation Rusty and dirty...

Page 15: ...arm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age of eight and also persons with reduced physical sensory or mental capabili...

Page 16: ...Notes 16...

Page 17: ...Notes 17 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm...

Page 18: ...Notes 18...

Page 19: ...ctions Bluetooth Low Energy BLE Ambient Operating Temp 10 50 C 50 122 F Tool Weight 55 g 0 1 lb Console Screen dimension 7 7in With Console Total Net Weight 1462 g 3 22 lb Total Package Dimensions Wei...

Page 20: ...anty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be vali...

Reviews:

Related manuals for B iRON 115T