background image

8

9

Before carrying out maintenance, always allow the equipment to cool. 

- Clean the station screen with a glass cleaner 

or  a damp cloth.

Clean  
periodically

- Use a damp cloth to clean the casing and 

the tool. Alcohol can only be used to clean 
the metal parts.

- Periodically check that the metal parts of 

the tool and stand are clean so that the 
station can detect the tool status. 

- Maintain tip surface clean and tinned prior 

to storage in order to avoid tip oxidation.  
Rusty and dirty surfaces reduce heat 
transfer to the solder joint.

- Periodically check all cables and tubes.

Maintenance

1.

 Pull off the fuse holder and remove the  

    fuse. If necessary use a tool to lever it off.

2. 

Press the new fuse into the fuse holder  

    and replace it in the station.

 
- Replace a blown fuse as follows:

- Replace any defective or damaged pieces. Use original JBC spare parts only. 

- Repairs should only be performed by a JBC authorized technical service.

  It is imperative to follow safety guidelines to prevent electric  
  shock, injury, fire or explosion. 

- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire. 
 
- The power cord must be plugged into approved bases. Be sure that it is properly grounded  
  before use. When unplugging it, hold the plug, not the wire.
 
-  Do not work on electrically live parts. 

- The tool should be placed in the stand when not in use in order to activate the sleep mode.  
  The soldering tip, the metal part of the tool and the stand may still be hot even when the station is  
  turned off. Handle with care, including when adjusting the stand position.

- Do not leave the appliance unattended when it is on. 

- Do not cover the ventilation grills. Heat can cause inflamable products to ignite. 
 
- Use a “non residue” classified flux and avoid contact with skin or eyes to prevent irritation. 
 
- Be careful with the fumes produced when soldering.

- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when  
  working to avoid personal harm. 

- Utmost care must be taken with liquid tin waste which can cause burns. 

- This appliance can be used by children over the age of eight and also persons with reduced 
  physical, sensory or mental capabilities or lack of experience provided that they have been given  
  adequate supervision or instruction concerning use of the appliance and understand the hazards  
  involved. Children must not play with the appliance. 

- Maintenance must not be carried out by children unless supervised.

Safety

www.jbctools.com

Summary of Contents for BT-A

Page 1: ...Soldering Station Ref BT A www jbctools com ...

Page 2: ...BT 9A 100V Brass Wool 1 unit Ref CL6210 General Purpose Handle 1 unit Ref T245 A Cartridges 2 units Ref C245906 x1 C245907 x1 Features Cable collector Quick Tip Changer Tip Cleaning System Stand Yellow LED SLEEP Green LED IN USE Dial Main switch Fuse Power Socket Equipotential connection General Purpose Handle Ref T245 A www jbctools com Soldering Station Ref BT A www jbctools com ...

Page 3: ...ed with 3 m For general use Works with C245 Cartridge range Compatible Handles Soft foam Ref 0016057 Non slip soft touch Blue grip to easily distinguish it from other handles Put the slip on tabs into the new grip Slide the grip with the tabs onto the handle To remove the tabs hold the grip and pull tabs new grip General Purpose Handle Ref T245 A Note All models are supplied with a 1 5 m cable Eas...

Page 4: ...continually in a overloaded condition for a period of time the system will stop and both leds will flash simultaniusly Switch station off and on to reset and review the soldering application Yellow LED SLEEP Green LED IN USE Dial The original parameters of control unit can be modified using the AC console It is necessary to connect the console AC with software revision 7 0 or later to the BT in or...

Page 5: ... must be plugged into approved bases Be sure that it is properly grounded before use When unplugging it hold the plug not the wire Do not work on electrically live parts The tool should be placed in the stand when not in use in order to activate the sleep mode The soldering tip the metal part of the tool and the stand may still be hot even when the station is turned off Handle with care including ...

Page 6: ...10 11 Exploded View www jbctools com ...

Page 7: ...BC s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear due to use or mis use In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased This product should not be thrown in the garbage In accordance with the European directive 20...

Reviews: