2. Inserting & Aligning
2. Replace
3. Fixing
3. Insert
Pull out the remaining solder
wire from the feed tube. Use a
pliers if necessary.
Pull the trigger repeatedly until
the solder wire appears at the
tip. Always use 0.8 - 1.0 mm
diameter solder wire.
Changing cartridge
Replacing solder wire
The
AP250-A Solder Feed Iron works with the C250 Cartridge Range
.
Find the model that best suits your soldering needs in
www.jbctools.com
To change a catridge safely, unplug the tool or turn the station off before following these guidelines:
Loosen the screw and remove
the cartridge.
Use a flat pliers if still hot.
1. Removing
1. Remove
Alignment
Important:
Tighten the screw
again being careful not to
over-tighten. This is necessary
for the tool to function.
Pull off the empty reel and fit
the new one.
Important:
Insert the cartrid-
ge as far as the mark for a
correct connection.
Align the tip of the cartridge
with the feed tube. Use a flat
pliers to correctly align the tip.
Mark