11
MAINTENANCE
Prior to maintenance or storage you must unplug
the equipment from the power supply and let it
cool down.
- Use a damp cloth to clean the case and the tool.
Alcohol can be used only to clean the metal parts.
- Check periodically that the metal parts of the
tool/stand are clean in order to have a good
detection when the tool is in the stand.
- Clean the station’s screen with a glass cleaner
or a damp cloth.
Unplug the station. Remove the fuse by pulling
the black cap. Help yourself with a lever tool if
necessary. See the fuse’s technical specifications
on the last page.
Place the new fuse into the holder by pushing
and place it again into the station.
Clean periodically
- Keep the tip surface clean and tinned prior to storage in order to avoid tip oxidation.
Rusty and dirty surfaces reduce heat transfer to the solder joint.
- Periodically check all cables and tubes connected.
- Replace any defective or damaged handpiece or tool.
- Replace the fuse if it is blown according to the following guidelines:
REPAIR
- Repairs should be performed only by a JBC’s authorized technical service.
- JBC offers you a professional after-sales service for your equipment.
- Use original JBC spare parts only. Otherwise this may lead to accidents.