Specifications
CD-1SQF
120V 50/60Hz. Input fuse: T2A. Output: 23.5V. Control Unit model:
CD-1F
CD-2SQF
230V 50/60Hz. Input fuse: T1A. Output: 23.5V. Control Unit model:
CD-2F
CD-9SQF
100V 50/60Hz. Input fuse: T2A. Output: 23.5V. Control Unit model:
CD-9F
- Output Peak Power CD-SF:
40W
- Temperature Range:
90 - 450 °C / 190 - 840 °F
- Idle Temp. Stability (still air):
±1.5ºC 7 ±3ºF (Meets and exceed IPC J-STD-001)
- Temp. accuracy:
±3% (Using reference cartridge)
- Temp. adjustment:
±50ºC / ±90ºF (Through station menu setting)
- Tip to ground voltage/resistance:
Meets and exceed
ANSI/ESD S20.20-2014 IPC J-STD-001F
- Earthing Fuse:
F 1.25A
- Connections:
USB connector station-PC
RJ12 Connector
- Ambient operating temp:
10 - 50 ºC / 50 - 122 ºF
- Control Unit Dimensions / Weight:
170 x 176 x 145 mm / 2.8 kg
- (L x W x H)
6.7 x 6.9 x 5.7 in / 6.17 lb
- Total Net Weight:
3 kg / 6.61 lb
- Total Package Damensin / Weight: 234 x 234 x 258 mm / 3.15 kg
(L x W x H)
9.2 x 9.2 x 10.2 in / 6.94 lb
Complies with CE standards
ESD protected housing “skin effect”