PIN
Change the default security
PIN number (0105).
The PIN must be entered every
time a parameter is changed.
Sound
Enable/disable the beep
sound of the keypad.
Warnings
Port Settings
Recommendations
Parameter Description
When the user changes
the cartridge type, the
parameter should be reset
to 0°C/F or to the value
needed for this cartridge.
E.g. If a correction of
+20°C (+36°F) is set for the
C245966 (thick type) and
then the user changes the
cartridge for a C245030
(which is thinner) without
resetting, they would be
working at a temperature
of +20°C (+36°F) lower for
the C245030 which does
not need any temperature
adjustment.
Temp Adjust
It provides a more precise
adjustment between the
selected temperature and the
current one.
Set values within ±50°C
(± 90°F) to achieve zero
deviation. JBC strongly
recommends the use of TID-A
or TIA-A Thermometers to
obtain precise readings.
Cartridge
Select the cartridge.
General Settings
Recommendations
Parameter Description
Warnings
Temp Units
Celsius (ºC) or Fahrenheit (ºF)
Date & Time
Set the Date and the Time.
www.jbctools.com