The sleep temperatures are
set to achieve a balance
between preventing oxidation
and reaching the working
temperature in a few seconds.
Sleep delay
Set the time that the tool
will remain at the selected
temperature when in the stand
before entering sleep mode.
The tip temperature will then
drop to the Sleep temperature.
Because our tools reach the
working temperature from the
deafult Sleep mode in only a
few seconds, this parameter is
preset to 0 min. Once the tool
is returned to the stand the
temperature will automatically
drop to the sleep temperature,
extending tip life and avoiding
oxidation. Retinning the tip
before placing the tool in the
stand will protect the tip and
extend its life.
Recommendations
Parameter Description
Warnings
Tools
Setting these
parameters to higher values
will unnecessarily accelerate
oxidation and shorten tip
life especially when working
with temperatures up to
450°C (840°F).
Sleep temp
This is the set temperature the
tip reaches when returned to
the stand.
Hibernation delay
Set the time the tool will
remain at Sleep temperature
before entering the Hibernation
mode. At this time, the power
supply is cut off and the tip
remains at room temperature.
Increasing the default
value will accelerate
oxidation and shorten the
tip life.
This function completely
protects the tip from oxidation
during long periods of
inactivity while the tool is in the
stand.
Retinning the tip before
placing the tool in the stand
also helps prevent oxidation
and extends the life of the tip.
Profiles
Enable/disbale profile funtion
Peripherals
Link connected peripherals
www.jbctools.com