background image

Notes

16

Summary of Contents for CP-9QF

Page 1: ...INSTRUCTION MANUAL CP Precision Rework Station ...

Page 2: ...3715 120V 0023714 230V Manual 1 unit Ref 0026946 Sponge 1 unit Ref S0354 Adjustable Micro Tweezers 1 unit Ref AM120 A Control Unit 1 unit This manual corresponds to the following references CP 9QF 100V CP 1QF 120V CP 2QF 230V Packing List The following items are included ...

Page 3: ...ble Collector Tip Cleaner with Antisplash Membrane Brass Wool inside Screen Adjustable Tool Holder Tip Exchanger Cartridge Holder Power Socket Main Switch Earth Fuse Equipotential Connection USB B Connector Fuse Fume Extractor Connector Tool Connector Wiper AM120 Adjustable Micro Tweezers C120 Cartuchos not included sold separately ...

Page 4: ... a small layer of solder on the tip preventing oxidation between cleaning and rewetting Wiper Ref CL7984 A temperature resistant receptacle for removing excess solder by gently tapping or wiping If the tip is very dirty JBC recommends first cleaning it with the wiper to remove excess solder The cable collector keeps the cable away from the work area and prevents the weight of the cable from distur...

Page 5: ...ool Metal Brush Ref CL6220 When used carefully it provides more thorough cleaning Sponge Ref S0354 Tapping Tap gently to remove excess solder Wiping Use the slots to remove the remaining particles Wiper Ref CL7984 The softest cleaning method Keep the sponge damp with distilled water when working to avoid tip wear not included sold separately 5 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manu...

Page 6: ...ridges in the extractor and pull to remove the cartride Place the tweezers on top of the new cartridge and press down slightly 3 Inserting Use the holes for fixing the cartridges Important It is essential to insert the cartridges up to the mark for a proper connection ...

Page 7: ...tions work with C120 cartridges and AM120 Ajustable Micro Tweezers Find the model that best suits your soldering needs in www jbctools com Compatible Cartridges 4 Rotational Cartridge Alignment Slightly turn the wheels to align the cartridges as required 5 Vertical Cartridge Alignment Close the tweezers and the rear wheel allows the cartridges to be equally aligned en vertical direction ...

Page 8: ... to recover tip temperature extremely quickly This allows the user to work at a lower temperature As a result tip life is five times longer than with other brands Tool Settings Sleep Change Sleep temperature and set Sleep delay from 0 to 9 min or no Sleep Tool Settings Hibernation Change Hibernation delay from 0 to 60 min or no Hibernation Long time in the stand 1 Work 2 Sleep 3 Hibernation When t...

Page 9: ...have selected temp levels The values must be adjusted for the task Temp Adjust parameter It provides a more precise adjustment between the selected temp and the actual one Earth Fuse warning is shown when fuse is blown Replace the fuse Menu Help Information Displays a specific fixed temp Selected Temperature Power Station troubleshooting available on the product page at www jbctools com Troublesho...

Page 10: ...s Main menu Main menu 4 Counters 5 Program version Tool 245 245 1 Fix one temp 2 Temp levels set OFF 3 Sleep delay 0 min Tool settings Tool settings 1 Plugged hours 0 2 Working hours 0 3 Sleep hours 0 4 Hibernation hours 0 Total Counters Total Counters 5 No tool hours 0 6 Sleep cycles 0 Back Back 4 Sleep temp 1500 C 5 Hibernationdelay 10 min 6 Temp adjust O O C Tool 245 245 Back Back Menu Screen D...

Page 11: ...nd its components Even in short time periods of tip contact with the soldering joint the flux may not work properly and could seriously reduce tip life If the solder joint requires more power e g multilayered or high dissipation boards JBC strongly recommends using other aids like preheaters Be careful when using these parameters as they may reduce the tip life if not used properly Please follow t...

Page 12: ... to change the temperature This allows a quick change between 3 different tempe ratures Set them according to the allowed values for your soldering applications Because our tools reach the working temperature from the deafult Sleep mode in only a few seconds this parameter is preset to 0 min Once the tool is returned to the stand the temperature will automatically drop to Sleep temperature extendi...

Page 13: ...to the value needed for this cartridge E g If a correction of 20 C 36 F is set for a thick cartridge and then the user changes to a thinner one whitout resetting the temperature adjustment he would be working at a higer temperature than needed for this thinner cartridge which does not need any temperature adjustment This function completely protects the tip from oxidation during long periods of in...

Page 14: ...ool s status Maintain the tip surface clean and tinned before storage to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables Replace any defective or damaged pieces Only use original JBC spare parts Repairs should only be performed by a JBC authorized technical service When this warning appears on the main screen earthing fuse must be...

Page 15: ...gnite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age of eight and also people with red...

Page 16: ...Notes 16 ...

Page 17: ...Notes 17 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm ...

Page 18: ...Notes 18 ...

Page 19: ...nd exceed IPC J STD 001 Temp Accuracy 3 Using reference cartridge Temp Adjustment 50ºC 90ºF Through station menu setting Tip to Ground Voltage Resistance Meets and exceed ANSI ESD S20 20 2014 IPC J STD 001F Earthing Fuse F 1 25A Connections USB connector station PC RJ12 connector Ambient Operating Temp 10 50 ºC 50 122 ºF Control Unit Dimensions Weight 170 x 176 x 145 mm 2 8 kg L x W x H 6 7 x 6 9 ...

Page 20: ...ranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased Get 1 extra year JBC warranty by registering here https www jbctools com productregistration within 30 days of purchase ...

Reviews: