Before carrying out maintenance or storage, always allow the equipment to cool.
- Clean the station’s screen with a glass cleaner
or a damp cloth.
Remove the fuse by pulling the black cap.
If necessary use a tool to lever it off.
Press the new fuse into the holder and
replace it in the station.
Clean
periodically
- Use a damp cloth to clean the casing and
the tool. Alcohol can only be used to clean
the metal parts.
- Check periodically that the metal parts of
the tool/stand are clean so that the station
can detect when the tool is in the stand.
- Maintain tip surface clean and tinned prior
to storage in order to avoid tip oxidation.
Rusty and dirty surfaces reduce heat
transfer to the solder joint.
- Periodically check all cable connections.
Maintenance
- Replace the fuse if it is blown according to the following guidelines:
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.