background image

www.jbctools.com

13

  It is imperative to follow safety guidelines to prevent electric  
  shock, injury, fire or explosion. 

- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause 
fire. 
 
- The power cord must be plugged into approved bases. Be sure that it is properly grounded  
before use. When unplugging it, hold the plug, not the wire.
 
-  Do not work on electrically live parts. Antistatic handle of soldering irons is electrically 
conductive. 
 
- The tool should be placed in the stand when not in use in order to activate the sleep mode.  
The soldering tip, the metal part of the tool and the stand may still be hot even when the station is 
turned off. Handle with care, including when adjusting the stand position.

- Do not leave the appliance unattended when it is on. 

-  Do not cover the ventilation grills. Heat can cause inflamable products to ignite even when  
out of  sight. 
 
- Use a “non residue” classified flux and avoid contact with skin or eyes to prevent irritation. 
 
- Be careful with the fumes produced when soldering.

- Keep your workplace clean and tidy. Wear appropriate protective glasses and gloves when 
working to avoid personal harm. 

- Utmost care must be taken with liquid tin waste which can cause burns. 

- This appliance can be used by children over the age of eight and also persons with reduced 
physical, sensory or mental capabilities or lack of experience provided that they have been given 
adequate supervision or instruction concerning use of the appliance and understand the hazards 
involved. Children must not play with the appliance. Maintenance shall not be carried out by 
children unless supervised.

Safety

Summary of Contents for CV-1D

Page 1: ...English www jbctools com Compact Desoldering Station with Pneumatic Pump Ref CV D ...

Page 2: ... The following items should be included CSV Control Unit Ref CSV 1D 120V CSV 2D 230V CSV 9D 100V Brass Wool Ref CL6210 Micro Desoldering Iron Ref DS360 A Sponge Ref S0354 Power Cord Ref 0009417 100V 120V 0009401 230V ...

Page 3: ...Tips 5 units Ref C360002 Tips 5 units Ref C360004 Cleaning Rods Ref 0008466 Filter 2 units Ref 0008473 Cleaning brush Ref 0008297 Solder Collector 2 units Ref 0008467 DS360 A Accessories Ref 0010259 50 Filter Box Ref 0005966 Suction Filter Ref 0821830 Module Cable connector Ref 0010207 Cotton Filters Ref 0781046 Escape Filter Ref 0008446 ...

Page 4: ...ed available compressed air at the operator s bench 4 Cable collector Tip Cleaning System Process Control Adjustable Stand Intelligent Heat Management Features Power Socket Main switch Equipotential connection Fuse USB B Micro Desoldering Iron Ref DS360 A Suction Filter Ref 0821830 ...

Page 5: ...www jbctools com 5 Adjustable Stand Cable collector Tilt the tool stand to suit your work position Place the cable on the collector and adjust to keep work area free of cable ...

Page 6: ...on the tip preventing oxidation between cleaning and rewetting Select the option that best suits your tip cleaning needs More options for the splashguard not supplied Inox Wool Ref CL6205 Provides a superior cleaning on the tip Metal Brush Ref CL6220 When used carefully it provides a more thorough cleaning Splashguard Tip Wipe Wiping Use the slots to wipe off any remaining particles Tapping Tap ge...

Page 7: ...nager www jbctools com manager html Manage and monitor as many stations as your Windows PC can handle by using the JBC Mana ger software You can export data to other PCs Register Settings Create graphs of the soldering process in real time with power and temperature data Manager Settings Change settings for a group of JBC stations at the same time any JBC station USB Hub Cable USB AB JBC Updater w...

Page 8: ...he user to work at a lower temperature As a result tip life increases x5 times 1 Work Lift tool from the stand and the tool tip will heat up to the selected temperature 2 Sleep When the tool is in the stand the temperature reduces to Sleep temperature pre set 260ºC 500ºF Tool in the stand A c t u a l T e m p 2 6 0 o C Sleep Tool in the stand after sleep No heat A c t u a l T e m p 2 0 o C Hibernat...

Page 9: ...en provides useful information of tool status in real time 0c Selected temp 350 o C P o w e r 1 0 Fixed temp 350 o C Displays a specific fixed temp Shown when you have selected temp levels Work Screen Process Control 1 Fix one temp 2 Temp levels set OFF 3 Sleep delay 0 min 5 Beep ON 6 Change PIN 1 Temp unit Celsius 2 Maximum temp 4000 C 3 Minimum temp 2000 C 4 Help text OFF Levels ºC 270 350 400 1...

Page 10: ...06 ØA 3 ØB 1 5 Ømax pin 1 3 Do not hold the tip on the spring clamp Changing the Tip 1 Remove the tip by using a flat nosed pliers Twist the tip and pull 2 Insert the new tip and follow the same steps conversely Compatible tips The CS and CV desoldering stations work with C360 tip range Find the model that best suits your desoldering needs on www jbctools com Tip selection Remember to select the b...

Page 11: ...717 Filter cover Ref 0004710 www jbctools com 11 Changing the Heating Element Filter Fixing screw Heating element Ref DSV DS 1 Pull off the filter and the solder collector 2 Undo the fixing screw indicated in the picture and remove the heating element 3 Insert the new heating element following the same steps conversely Changing the Pump Filters Solder Collector Escape Filter Ref 0008446 ...

Page 12: ...ed when cleaning the metal parts Periodically check that the metal parts of the tool stand are clean so that the station can detect when the tool is in the stand Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables tubes and filters to ensure proper solder suction Maint...

Page 13: ...e stand position Do not leave the appliance unattended when it is on Do not cover the ventilation grills Heat can cause inflamable products to ignite even when out of sight Use a non residue classified flux and avoid contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protective glasses and gloves whe...

Page 14: ...14 Exploded View ...

Page 15: ...56 842 F Output Peak Power 40W Tip to ground resistance 2 ohms Safety transformer mains separator and double isolation Ambient operating temp 10 40 ºC 50 104 ºF USB connector station PC MV A Total weight and size 0 7 kg 1 6 lb 145 x 55 x 225 mm Air pressure range supply 4 6 bar Vacuum at 6 bar 90 680mmHg 26 8 inHg Flow rate 15 SLPM Comply with CE standards ESD protected housing skin effect www jbc...

Page 16: ...product wear due to use or mis use In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased This product should not be thrown in the garbage In accordance with the European directive 2002 96 EC electronic equipment at the end of their life must be collected and returned to an authorized recycling facility www jbctools com ...

Reviews: