background image

2 Tools DDE 

Precision Station

Ref. DDPE-QB

INSTRUCTION MANUAL

www.jbctools.com

Summary of Contents for DDPE-2QB

Page 1: ...2 Tools DDE Precision Station Ref DDPE QB INSTRUCTION MANUAL www jbctools com ...

Page 2: ...DPE QB DDE Control Unit 1 unit Ref DDE 1C 120V DDE 2C 230V DDE 9C 100V Brass Wool 1 unit Ref CL6210 Adjustable Micro Tweezer 1 unit Ref AM120 A Stand 1 unit Ref AM SA Power cord 1 unit Ref 0024080 230V 0023717 120V 0024077 100V General Purpose Handle 1 unit Ref T210 A Manual 1 unit Ref 0025139 Cartridge holder 1 unit Ref SCH A ESD Tip Cleaner 1 unit Ref CL8499 2 www jbctools com ...

Page 3: ...ls connector USB B connector Power Socket Stand Cable Ref 0011283 Precision Purpose Handle Ref T210 A Tilt the display for easy reading Stand Ref AD SE Stand Ref AM SA USB A connector 2 8 Color TFT screen Main Switch Adjustable Micro Tweezers Ref AM120 A www jbctools com 3 ...

Page 4: ...layed if temperature levels are activated Station Tools Counters Reset Language Peripherals Set the station parameters Set the tool parameters Consult modify the links of the peripherals connected to the station with the port they are connected to Display the hours worked in each cycle It is possible to choose the language from a list Allows you to carry out an overall station reset restoring all ...

Page 5: ... Ceramic Chip components like MLCC this new and unique feature allows controlling the heating ramp up rate of the tool to gradually increase the temperature of the component through all the phases of the soldering process Up to 25 fully configurable soldering profiles can be stored USB flash drive is connected Station is controlled by a PC Station is controlled by a robot System notifications Station...

Page 6: ...ing to your work needs Select how the pedal acts as Sleep Extractor hibernation or as a module switch Select the activating mode of the pedal pressed released Set the duration of the activation time when pressing the pedal once For continuous functioning keep the pedal pressed NB The same can be applied inversely when continually pressing the pedal and releasing to activate These references are no...

Page 7: ... thanks to the Sleep and Hibernation modes which increase up to 5 times the life of the tip 3 Hibernation 1 Work 2 Sleep When the tool is lifted from the stand the tip will heat up to the selected temperature When the tool is in the stand the temperature falls to the preset Sleep temperature After longer periods of inactivity the power is cut off and the tool cools down to room temperature Long pe...

Page 8: ... Sealing Plug Replacement Before replacing the sealing plug unplug the power supply and make sure the device is not hot Note the Sealing Plug mount ing position The chamfered side has to be positioned towards the Handle 2 Mounting position 3 Inserting the Sealing Plug 1 Removing the Sealing Plug Sealing Plug Handle Gently push the Sealing Plug inside the handle until it is completely into the Hand...

Page 9: ...he holes to fix the cartridge as follows A For curved C210 B For C245 C For straight C210 D cartridge Storage rack Save time and change cartridges safely without switching the station off Be careful the cartridges may be hot when placing them in the storage rack Important It is essential to insert the cartridge as far as the mark for a proper connection Mark B C A D www jbctools com 9 ...

Page 10: ... press down 3 Inserting 4 Rotational Cartridge Alignment Use the grooves to insert the cartridges as far as the mark Slightly turn the wheels to align the cartridges as required 5 Vertical Cartridge Alignment The rear wheel allows the cartritges to be equally aligned when you close the tweezers Important It is essential to insert the cartridges as far as the mark for a proper connection 10 ...

Page 11: ...e brass wool ESD Tip Wiper Ref CL0240 A temperature resistant receptacle lets the operator remove excess solder by gentle tapping or wiping Antisplash Membrane Ref 0017574 Prevents splashing to maintain the work area clean Non slip base Sponge Ref S0354 No need to hold the base while cleaning tips The least harmful cleaning method Keep the sponge damp with distilled water when working to avoid tip...

Page 12: ...asic working system Peripherals Control Unit Stand Tool Cartridge Range MSE A MVE A MNE A FSE A P 005 DDE C AD SE T210 A C210 T245 A C245 DN SE T210 NA C210 T245 NA C245 AP SE AP250 A C250 PA SE PA120 A C120 HT SE HT420 A C420 DS SE DS360 A C360 DR SE DR560 A C560 12 ...

Page 13: ...ed to clean the metal parts Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables and tubes Replace a blown fuse as follows Replace any defective or dam...

Page 14: ...can cause inflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protective glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age...

Page 15: ...DE 烙铁头 O O O O O O 手柄 O O O O O O 电源线 O O O O O O 主机 O O O O O O 电源插座 O O O O O O 保险丝 O O O O O O 主开关 O O O O O O 电位连接 X O O O O O 变压器 O O O O O O 线路板 X O O O O O O 表示该有害物质在该部件所有均质材料中的含量均在GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出GB T 26572 规定的限量要求 www jbctools com 15 ...

Page 16: ...ion within 30 days of purchase www jbctools com 0025139 0620 Specifications 2 Tools DDE Precision Station DDPE 1QB DDPE 2QB DDPE 9QB DDE 1C 120V 50 60Hz Input fuse 4A Output 23 5V DDE 2C 230V 50 60Hz Input fuse 2A Output 23 5V DDE 9C 100V 50 60Hz Input fuse 5A Output 23 5V Temperature Range 90 450 C 190 840 ºF Idle Temp Stability still air 1 5 ºC 3 ºF Output Peak Power 150W per tool Tip to ground ...

Reviews: