background image

Peripherals

Port 2-PA

17:14

Pedal

PD_a

Module

MSE

Pedal

PD_a
PD_b

None

Peripherals

Port 2-PA

17:14

Pedal

PD_a

Module

MSE

Peripherals

Port 2-PA

17:14

Pedal

PD_a

Function

Extractor

Mode

released

Minimum time

0 sec

Back

Peripherals

Port 2-DR

17:14

Pedal

None

Module

None

Module

MSE_a

None

Pedal Initial Set up 

(Ref. P-005)*

1.

Enter the 

Peripherals 

Menu

 

and 

select the

port

 which you want to join to the pedal.

2.

Select the pedal from the list (

Note that your

first connection is denoted as “a”, the second
being “b”, etc. (e.g. PD_a, PD_b,...)

.

3.

Set the pedal function according to your work needs:

Select how the pedal 
acts: as 

Sleep

Extractor

 (hibernation) 

or as a 

module

 switch.

Select the activating 
mode of the pedal
(

pressed

/

released

)

Set the duration 
of the activation 
time when pressing 
the pedal once**. 
For continuous 
functioning keep the 
pedal pressed.

**NB: The same can be applied inversely when continually pressing the pedal and releasing to activate.

* These references are not included

1.

After connecting the module, enter the

Peripherals Menu and select the port which
you want to join with the module.

2.

Select the module from the list of peripheral

connections. Remember your first connection
is denoted as “a”, the second being “b”, etc.
(e.g. MS_a, MS_b,...).

3.

Press Menu or Back to save changes.

MSE/MVE Initial Set up 

(Ref. MSE-A / Ref. MVE-A)

*

6

Summary of Contents for DDPE-QB

Page 1: ...2 Tools DDE Precision Station Ref DDPE QB INSTRUCTION MANUAL www jbctools com...

Page 2: ...PE QB DDE Control Unit 1 unit Ref DDE 1C 120V DDE 2C 230V DDE 9C 100V Brass Wool 1 unit Ref CL6210 Adjustable Micro Tweezer 1 unit Ref AM120 A Stand 1 unit Ref AM SA Power cord 1 unit Ref 0024080 230V...

Page 3: ...s connector USB B connector Power Socket Stand Cable Ref 0011283 Precision Purpose Handle Ref T210 A Tilt the display for easy reading Stand Ref AD SE Stand Ref AM SA USB A connector 2 8 Color TFT scr...

Page 4: ...ayed if temperature levels are activated Station Tools Counters Reset Language Peripherals Set the station parameters Set the tool parameters Consult modify the links of the peripherals connected to t...

Page 5: ...Ceramic Chip components like MLCC this new and unique feature allows controlling the heating ramp up rate of the tool to gradually increase the temperature of the component through all the phases of t...

Page 6: ...ng to your work needs Select how the pedal acts as Sleep Extractor hibernation or as a module switch Select the activating mode of the pedal pressed released Set the duration of the activation time wh...

Page 7: ...thanks to the Sleep and Hibernation modes which increase up to 5 times the life of the tip 3 Hibernation 1 Work 2 Sleep When the tool is lifted from the stand the tip will heat up to the selected temp...

Page 8: ...Sealing Plug Replacement Before replacing the sealing plug unplug the power supply and make sure the device is not hot Note the Sealing Plug mount ing position The chamfered side has to be positioned...

Page 9: ...e holes to fix the cartridge as follows A For curved C210 B For C245 C For straight C210 D cartridge Storage rack Save time and change cartridges safely without switching the station off Be careful th...

Page 10: ...press down 3 Inserting 4 Rotational Cartridge Alignment Use the grooves to insert the cartridges as far as the mark Slightly turn the wheels to align the cartridges as required 5 Vertical Cartridge Al...

Page 11: ...brass wool ESD Tip Wiper Ref CL0240 A temperature resistant receptacle lets the operator remove excess solder by gentle tapping or wiping Antisplash Membrane Ref 0017574 Prevents splashing to maintai...

Page 12: ...sic working system Peripherals Control Unit Stand Tool Cartridge Range MSE A MVE A MNE A FSE A P 005 DDE C AD SE T210 A C210 T245 A C245 DN SE T210 NA C210 T245 NA C245 AP SE AP250 A C250 PA SE PA120...

Page 13: ...d to clean the metal parts Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status Maintain tip surface clean and tinned prior to storage...

Page 14: ...an cause inflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear...

Page 15: ...Pb Hg Cd Cr VI PBB PBDE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O O O X O O O O O O GB T 26572 X GB T 26572 www jbctools com 15...

Page 16: ...tion within 30 days of purchase www jbctools com 0025139 0620 Specifications 2 Tools DDE Precision Station DDPE 1QB DDPE 2QB DDPE 9QB DDE 1C 120V 50 60Hz Input fuse 4A Output 23 5V DDE 2C 230V 50 60Hz...