background image

Safety

- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire. 
 
- The power cord must be plugged into approved bases. Be sure that it is properly grounded  
  before use. When unplugging it, hold the plug, not the wire. 
 
- Do not work on electrically live parts. 
 
- The tool should be placed in the stand when not in use in order to activate the sleep mode.  
  The soldering tip, the metal part of the tool and the stand may still be hot even when the station is  
  turned off. Handle with care, including when adjusting the stand position.

- Do not leave the appliance unattended when it is on. 

- Do not cover the ventilation grills. Heat can cause inflamable products to ignite. 

- Avoid flux coming into contact with skin or eyes to prevent irritation.

- Be careful with the fumes produced when soldering.

- Keep your workplace clean and tidy. Wear appropriate protective glasses and gloves when  
  working to avoid personal harm. 

- Utmost care must be taken with liquid tin waste which can cause burns. 

- This appliance can be used by children over the age of eight and also persons with reduced 
  physical, sensory or mental capabilities or lack of experience provided that they have been given  
  adequate supervision or instruction concerning use of the appliance and understand the hazards  
  involved. Children must not play with the appliance. 

- Maintenance must not be carried out by children unless supervised.

  It is imperative to follow safety guidelines to prevent electric  
  shock, injury, fire or explosion. 

8

Summary of Contents for DDSE-9C

Page 1: ...INSTRUCTION MANUAL Premium Rework station with Electric Pump Ref DDSE B www jbctools com...

Page 2: ...MSE A Module Cable 1 unit Ref 0014874 DDE Control Unit 1 unit Ref DDE 1B 120V DDE 2B 230V DDE 9B 100V Brass Wool 1 unit Ref CL6210 Desoldering Iron 1 unit Ref DR560 A Stand 1 unit Ref DR SE Power cord...

Page 3: ...0812630 Tips 3 units Ref C560005 x1 Ref C560013 x1 Ref C560004 x1 Tip cleaning set 1 unit Ref 0965970 Long Tip Cleaning set 1 unit Ref 0965760 Manual 1 unit Ref 0020487 Suction Filter 1 unit Ref 08218...

Page 4: ...simultaneously with up to 2 tools and join each station port with 1 module 1 pedal Peripherals Stand Ref AD SE RJ12 connector for Robot USB B connector Equipotential connection Power Socket Desolderin...

Page 5: ...lter Ref 0821830 Module Cable Ref 0014874 USB A connector 2 8 Color TFT screen Tilt the display for easy reading Electric Desoldering Module Ref MSE A To another peripheral To Pedal Ref P 005 www jbct...

Page 6: ...or is required If you need to connect the MS MV MN or FS modules an adapter is required Ref IM2496 Basic working system Peripherals Control Unit Stand Tool Cartridge Range MSE A MVE A MNE A FSE A P 00...

Page 7: ...ohol can only be used to clean the metal parts Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status Maintain tip surface clean and tin...

Page 8: ...an cause inflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear...

Page 9: ...Pb Hg Cd Cr VI PBB PBDE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O O O X O O O O O O GB T 26572 X GB T 26572 www jbctools com 9...

Page 10: ...l Temperature Range 90 450 C 190 840 F Idle Temp Stability still air 1 5 C 3 F Tip to ground resistance 2 ohms Tip to ground voltage 2mV RMS Ambient Operating Temperature 10 40 C 50 104 F Communicatio...

Page 11: ...Exploded View www jbctools com 11...

Page 12: ...our website Warranty JBC s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misu...