background image

Glass Solder Collector Cleaning

1. Removing the lid 

3. Inserting the glass solder collector

Check filter

Lid

Check 
internal joint

2. Cleaning

Check the filter and replace it if it is dirty or 
damaged.

Remove the coil and clean the inside of the glass 
solder collector with the cleaning stick.

The lid must be unscrewed with the DR560 in a 
vertical position.

The glass solder collector must be inserted 
with coil filter in place, positioned between the 
2 lines marked. 

Then the whole unit must be closed by 
screwing the lid.

Marks

www.jbctools.com

15

Summary of Contents for DMPVE-QA

Page 1: ...4 Tools DME Station with Pneumatic Pump Ref DMPVE QA INSTRUCTION MANUAL www jbctools com...

Page 2: ...6217 Pneumatic Desoldering Module 1 unit Ref MVE A Brass Wool 1 unit Ref CL6210 Desoldering Iron 1 unit Ref DR560 A Stand 1 unit Ref DR SE General Purpose Handle 1 unit Ref T245 A Cotton Filter 1 unit...

Page 3: ...Ref SCH A Ref DMPVE QA DR560 Accessories Ref 0022819 Internal gasket 1 unit Ref 0019208 It contains 2 gaskets Filter Box 1 unit Ref 0780840 It contains 10 filters Spanner 1 unit Ref 0780550 Glass sol...

Page 4: ...tractors USB B connector Equipotential connection Power Socket RJ12 connector for PSE RJ45 connector for LAN Stand Ref DR SE Stand Cable Ref 0011283 Connections Stand Ref AD SE Desoldering Iron Ref DR...

Page 5: ...21830 Module Cable Ref 0014874 Pneumatic Desoldering Module Ref MVE A To another peripheral To Pedal Ref P 405 Air pressure 4 6 bar Tubing 4x 6 mm Not supplied Adjustable Micro Tweezers Ref AM120 A Pr...

Page 6: ...5 Station Information Help for each parameter Power indicator Shows the power delivered by the tool Tool in use Press on the tool image to see the Ports Screen Cartridge in use Introduce the reference...

Page 7: ...ns that complement and support your work Advanced functionalities It provides detailed graphics of tip temperature and power delivery in real time during solder joint formation for analysis purposes T...

Page 8: ...dule press Setup in the popup window MVE Initial Setup After connecting the pneumatic desoldering module MVE A a popup window is opened 2 Select the module from the list of peripheral connections Reme...

Page 9: ...rther reduced thanks to the Sleep and Hibernation modes which increase up to 5 times the life of the tip 1 Work 2 Sleep When the tool is lifted from the stand the tip will heat up to the selected temp...

Page 10: ...be displayed on the screen s status bar After inserting the cartridge introduce the last 3 numbers of its reference Desoldering process Use a tip with a larger diameter than the pad to achieve maximu...

Page 11: ...ridges safely without switching the station off Be careful the cartridges may be hot when placing them in the storage rack Important It is essential to insert the cartridge as far as the mark for a pr...

Page 12: ...e cartridges are in good condition so that the tweezers work properly The tail wheel guarantees that the cartridges are equally aligned with vertical symmetry AM120 Changing cartridges Unlock the fixi...

Page 13: ...brass wool ESD Tip Wiper Ref CL0240 A temperature resistant receptacle lets the operator remove excess solder by gentle tapping or wiping Antisplash Membrane Ref 0017574 Prevents splashing to maintai...

Page 14: ...ing Push the release ring to remove the pneumatic tubing Release ring 1 2 DR560 Maintenance The intake tube should be periodically cleaned with the largest rod possible Important DO NOT press the vacu...

Page 15: ...if it is dirty or damaged Remove the coil and clean the inside of the glass solder collector with the cleaning stick The lid must be unscrewed with the DR560 in a vertical position The glass solder c...

Page 16: ...and remove the fuse If necessary use a tool to lever it off 2 Press the new fuse into the fuse holder and replace it in the station Use a damp cloth to clean the casing and the tool Alcohol can only b...

Page 17: ...inflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropria...

Page 18: ...Pb Hg Cd Cr VI PBB PBDE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O O O X O O O O O O GB T 26572 X GB T 26572 18...

Page 19: ...g Temperature 10 50 C 50 122 F Connectors RJ12 for RS232 robot and for PSE Power Supply RJ45 connector for LAN Ethernet USB A USB B Peripherals connectors Control Unit Weight 4 6 kg 10 lb Control Unit...

Page 20: ...JBC s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the w...

Reviews: