background image

Maintenance

Before carrying out maintenance or storage, always unplug the tool.

- Check periodically that the metal parts are clean to ensure it is detected when on the stand.
  Always use a damp cloth or alcohol.

- Periodically check all cables and tubes connections.

- Replace any defective or damaged pieces. Use original JBC spare parts only.

- Repairs should only be performed by a JBC authorized technical service.

Glass Solder Collector Maintenance

2.

 Next remove the spiral and clean the inside 

part of the collector with the cleaning stick.

- Check the filter and replace it if it is dirty or 
damaged.

1.

 For cleaning, the top must be unscrewed with

  the DR560 in a vertical position.

3. 

Insert the filter and the spiral filter which must 

be inserted in place between the 2 lines on the 
solder collector. 
Before placing, make sure to insert the internal 
gasket into the solder collector.
Finally screw on the top to close the unit. 

Check filter

Check 
internal joint

2

3

1

6

Summary of Contents for DR5500

Page 1: ...Desoldering Iron Ref DR560 A English 2 Page Español 10 www jbctools com ...

Page 2: ... set 1 u Ref 0965970 Internal gasket 1 u Ref 0019208 It contains 2 gaskets Filter box 1 u Ref 0780840 It contains 10 filters Spanner 1 u Ref 0780550 Spiral Filter 1 u Ref 0812330 Long tip cleaning set 1 u Ref 0965760 Cleaning stick 1 u Ref 0786640 Metal Solder Collector 1 u Ref 0812630 Glass Solder Collector 1 u Ref 0812620 Manual 1 u Ref 0008867 DR560 A Desoldering Iron accessories included in th...

Page 3: ...solder remains left on a terminal just resolder it with fresh solder and repeat the desoldering operation Connection Desoldering Iron Ref DR560 A Tip Ref C560003 to desoldering module to stand Suction Filter Ref 0821830 Supplied with desoldering module 1 Apply the tip so that it fits over the component terminal 2 When the solder liquefies gently rotate the tip so that the terminal can be lifted of...

Page 4: ... C560 001 A 1 4 B 0 6 max pin 0 4 mm A 0 05 B 0 02 max pin 0 01 in C560 002 A 1 8 B 0 8 max pin 0 6 mm A 0 07 B 0 03 max pin 0 02 in C560 003 A 2 7 B 1 max pin 0 8 mm A 0 1 B 0 04 max pin 0 03 in C560 004 A 3 2 B 1 3 max pin 1 1 mm A 0 12 B 0 05 max pin 0 04 in C560 009 A 5 B 1 3 max pin 1 1 mm A 0 19 B 0 05 max pin 0 04 in C560 014 A 2 5 B 0 8 max pin 0 6 mm A 0 09 B 0 03 max pin 0 02 in Compatib...

Page 5: ...ering Iron Ref 5600010 In this case you must take out the washer with a pliers 1 Removing Loosen the deposit lid a remove the screw b and withdraw the heating element c 2 Placing Insert the new one a tighten the lid b and then the screw c For this operation turn off the station or disconnect the tool and wait until the tool temperature drops to room temperature Recommended Remove the lid in a vert...

Page 6: ...authorized technical service Glass Solder Collector Maintenance 2 Next remove the spiral and clean the inside part of the collector with the cleaning stick Check the filter and replace it if it is dirty or damaged 1 For cleaning the top must be unscrewed with the DR560 in a vertical position 3 Insert the filter and the spiral filter which must be inserted in place between the 2 lines on the solder...

Page 7: ...rod possible to clean the tip Important DO NOT press the pushbutton vacuum pump while tinning the desoldering tip as the fumes given off by the flux would quickly soil the ducts and filter of the air circuit www jbctools com 7 ...

Page 8: ...ul with the remains of liquid tin In contact with skin it can cause burns Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm This appliance can be used by children over the age of eight and persons with reduced p...

Page 9: ... Weight 0 4 kg 0 91 lb Complies with CE standards ESD protected housing skin effect Specifications www jbctools com 9 ...

Page 10: ...ef 0019208 Contiene 2 juntas Filter box Caja de filtros 1 ud Ref 0780840 Contiene 10 filtros Spanner Llave para puntas 1 ud Ref 0780550 Spiral Filter Filtro en espiral 1 ud Ref 0812330 Long tip cleaning set Juego largo de limpieza de puntas 1 ud Ref 0965760 Cleaning stick Bastoncillo de limpieza del depósito 1 ud Ref 0786640 Metal Solder Collector Depósito metálico de estaño 1 ud Ref 0812630 Glass...

Page 11: ... de vacío se detiene esto es para asegurar que el circuito de aspiración se vacíe completamente Si algún terminal ha quedado con restos de soldadura después de intentar desoldarlo suéldelo de nuevo y repita la operación 1 Apoye la punta del desoldador de modo que el terminal penetre dentro del orificio de la punta 2 Cuando la soldadura se licúe gire suavemente la punta del desoldador hasta que ter...

Page 12: ...a buena estanqueidad 250º C min C560 001 A 1 4 B 0 6 max pin 0 4 mm A 0 05 B 0 02 max pin 0 01 in C560 002 A 1 8 B 0 8 max pin 0 6 mm A 0 07 B 0 03 max pin 0 02 in C560 003 A 2 7 B 1 max pin 0 8 mm A 0 1 B 0 04 max pin 0 03 in C560 004 A 3 2 B 1 3 max pin 1 1 mm A 0 12 B 0 05 max pin 0 04 in C560 009 A 5 B 1 3 max pin 1 1 mm A 0 19 B 0 05 max pin 0 04 in C560 014 A 2 5 B 0 8 max pin 0 6 mm A 0 09 ...

Page 13: ...tirar la pestaña con la ayuda de unos alicates 1 Retire Desenrosque el tapón del depósito a retire el tornillo b y extraiga el elemento calefactor c 2 Coloque Inserte el nuevo cartucho a apriete el tapón del depósito b y luego apriete el tornillo c Para realizar esta operación debe apagar la estación o desconectar la herramienta y esperar que la punta esté a temperatura ambiente Recomendado Retire...

Page 14: ...sólo podrá ser realizada por un servicio técnico oficial JBC Mantenimiento del depósito de estaño 2 Seguidamente extraemos el filtro y la espiral y limpiaremos el interior con una baqueta En caso de que el filtro estuviera dañado sucio o degradado debe cambiarlo 1 Desenrosque el tapón y retirar el depósito con el desoldador en posición vertical 3 Vuelva a poner en el depósito el filtro y la espira...

Page 15: ...e la baqueta más larga con el fin de limpiar el tubo de aspiración Importante NO presione el botón de la he rramienta mientras se estaña la punta ya que los gases producidos podrían manchar rápida mente los conductos y el filtro www jbctools com 15 ...

Page 16: ...o con los restos de estaño líquido En contacto con la piel pueden causar quemaduras Evite el contacto del Flux con la piel o los ojos para prevenir la irritación Tenga precaución con el humo producido al trabajar Mantenga su lugar de trabajo limpio y ordenado Use gafas y guantes de protección adecuados Así evitará cualquier daño Este aparato puede ser utilizado por personas a partir de 8 años y ta...

Page 17: ... Peso 0 4 kg 0 91 lb Cumple con las normativas CE Seguridad ESD Especificaciones www jbctools com 17 ...

Page 18: ...Exploded View Despiece 18 ...

Page 19: ...www jbctools com 19 ...

Page 20: ...nd of their life must be collected and returned to an authorized recycling facility Garantía Esta garantía de 2 años cubre este equipo contra cualquier defecto de fabricación incluyendo la sustitución de partes defectuosas y mano de obra La garantía no cubre el desgaste del producto por uso o mal uso Para que esta garantía sea válida el equipo debe ser devuelto a portes pagados al distribuidor don...