background image

FRONT

Maintenance and Filter Replacement

- The fume extractor unit indicates by means 

of display and LED’s that the filters need to  
be replaced.

- To replace the filters remove the cover by 

opening the quick release levers, located 
on both sides of the casing.

- If the saturation indicator remains in red 

after replacing the pre-filter, it means that 
the compact filter is saturated and must 
also be replaced (see figure below).

- After replacing the compact filter, the 

carbon filter counter must be reset (Main 
Menu > Filter Set > Reset Carbon).

- The service life of the compact filter is 

a maximum of 1 year after opening its 
packaging. 

- If the filter is changed while the fume 

extractor is switched on, the fume extractor 
unit automatically starts the filter detection 
process and activates the aspiration for a few 
seconds.

Cover

Casing

Pre-Filter

Compact Filter

Connect the filter tube to the 
quick-coupling placed on the metal 
sheet 

       The filter has a given position.
Make sure the filter ribs mate with 
the corresponding slots.

Quick Release 
Lever

Filter 
Ribs

14

Summary of Contents for FAE1H

Page 1: ...FAE1H Fume Extractor for 1 Workbench HEPA 14 INSTRUCTION MANUAL...

Page 2: ...unit Ref 0024420 Power Cable 1 unit Ref 0023715 100V 120V 0023714 230V Premium Station Cable RJ12 male 2 units Ref 0019751 Compact Station Adapter RJ12 to USB A 1 unit Ref 0023504 Compact Station Cab...

Page 3: ...h Dispaly USB B Compact Stations Connection Pedal Connection RJ12 Premium Station Connections Filter Saturation Indicator Green Filter OK Yellow 20 carbon lifetime or about to saturate Red End of carb...

Page 4: ...assembled onto the workbench with the included clamp FAE020 Flexible Arm 50 Lenght 1 m 39 37 in To be inserted and screewed directly onto the workbench hole drilling required FAE010 Flexible Hose 50 L...

Page 5: ...drilling required FAE010 Flexible Hose 50 Lenght 1 5 m 59 05 in For connecting either to a flexible arm or to a accessory for the stand aspiration Attention Avoid awkward positions in order to minimi...

Page 6: ...l connected to a station can control the aspiration system Each Station detects the fume extractor as FAE_a The tool that should activate the fume extraction need to be configured through the peripher...

Page 7: ...can be updated via the USB B connection by means of JBC Updater software Download software from www jbctools com software html Note For the updating process the Premium Station Cable RJ12 has to be d...

Page 8: ...it 1 Continuous mode OFF 2 Beep ON 3 PIN OFF 4 Change PIN Port Port 1 Program Ctm 100 2 Delay to stop 3 Pedal Back Back 5 Workbench 1 Back Back Delay to stop Delay to stop 1 Work area 5 sec Back Back...

Page 9: ...k Total Counters Total Counters 1 Plugged hrs 100 2 Idle hrs 10 3 Work area hrs 70 4 Stand hrs 20 5 Work area cys 10 Back Back Partial Counters Partial Counters 1 Plugged hrs 100 2 Idle hrs 10 3 Work...

Page 10: ...fume extractor before modifying any parameter Unit Parameteter Continuous mode Beep PIN Change PIN Workbench Description Eanable disable continuous aspiration Fume extractor aspirations remains active...

Page 11: ...ol is returned to it range 0 999 seconds By default stand time is 60 seconds Delay to stop Work area It sets the time that a fume extractor keeps aspirating fumes at the work area once the tool is ret...

Page 12: ...d on the main screen When 0 is reached the system will show pop up message STOP 1 to replace the filter Saturation It shows saturation status of HEPA carbon filter set expressed in It is also displaye...

Page 13: ...0Hz Mode 1 Workbench Mode 2 Workbenches Flexible Arm Aspiration Intake 1 2 Stand Aspiration Intake 1 Not available Flow per Flexible Arm Intake 80 m3 h 47 08 cfm 75 m3 h 44 14 cfm Preset Aspiration Pr...

Page 14: ...ter replacing the compact filter the carbon filter counter must be reset Main Menu Filter Set Reset Carbon The service life of the compact filter is a maximum of 1 year after opening its packaging If...

Page 15: ...the safety guidelines to do the equipment maintenance safely Compact Filter includes activated carbon filter and particle filter HEPA 14 filter EN 1822 Accessories FAE1200 Filter for FAE1 FAE1110 Pre...

Page 16: ...oogles and gloves when handling polluted filters or pre filters Do not use the equipment without the filters Saturated filters can not be cleaned and reused Avoid blowing out the filter or the dirty p...

Page 17: ...Notes 17 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm...

Page 18: ...Notes 18...

Page 19: ...1 Noise 55 dB 1m FAE1 with 1 Workbench configuration and Low apsiration program Pre Filter Medium Dust Filter M5 EN 779 Compact Filters Particle Filter HEPA 14 EN 1822 Activated Carbon Filter Connecti...

Page 20: ...C s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warr...

Reviews: