15
Safety
- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.
- The power cord must be plugged into approved bases. Be sure that it is properly grounded before
use. When unplugging it, hold the plug, not the wire.
- Do not work on electrically live parts.
- The tool should be placed in the stand when not in use in order to activate the sleep mode. The
soldering tip or nozzle, the metal part of the tool and the stand may still be hot even when the station
is turned off. Handle with care, including when adjusting the stand position.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- Avoid flux coming into contact with skin or eyes to prevent irritation.
- Be careful with the fumes produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working
to avoid personal harm.
- Utmost care must be taken with liquid tin waste which can cause burns.
- This appliance can be used by children over the age of eight and also persons with reduced physical,
sensory or mental capabilities or lack of experience provided that they have been given adequate
supervision or instruction concerning use of the appliance and understand the hazards involved.
Children must not play with the appliance.
- Maintenance must not be carried out by children unless supervised.
It is imperative to follow safety guidelines to prevent electric
shock, injury, fire or explosion.
Specifications
HD
Heavy Duty Station
Ref.:
HDE-9D
100V 50/60Hz. Input fuse: 4A. Output: 42V.
Ref.:
HDE-1D
120V 50/60Hz. Input fuse: 4A. Output: 42V.
Ref.:
HDE-2D
230V 50/60Hz. Input fuse: 2A. Output: 42V.
- Output Peak Power:
250W
- Temperature Range:
90 - 500 °C / 190 - 932 °F
- Idle Temp. Stability (still air):
±1.5ºC / ±3ºF (Meets and exceed IPC J-STD-001F)
- Temp Accuracy: ±3% (using reference cartridge)
- Temp Adjustment: ±50ºC / ±90ºF Through station menu setting
- Tip to Ground Voltage/Resitance: Meets and exceed
ANSI/ESD S20.20-2014 IPC J-STD-001F
- Ambient Operating Temp.:
10 - 50 ºC / 50 - 122 ºF
- Connections:
USB-A / USB-B / Peripherals connectors
RJ12 connector for Robot
- Control Unit Dimensions:
232 x 148 x 120 mm / 9.13 x 5.83 x 4.72 in
- Total Net Weight:
5.37 kg / 11.84 lb
- Total Package Dimension / Weight: 368 x 368 x 195 mm / 6.19 kg
(L x W x H) 14.49 x 14.49 x 7.68 in / 13.65 lb
Complies with CE standards.
ESD safe.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm