background image

15

Safety

- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.

- The power cord must be plugged into approved bases. Be sure that it is properly grounded before 

use. When unplugging it, hold the plug, not the wire.

- Do not work on electrically live parts.

- The tool should be placed in the stand when not in use in order to activate the sleep mode. The 

soldering tip or nozzle, the metal part of the tool and the stand may still be hot even when the station 
is turned off. Handle with care, including when adjusting the stand position.

- Do not leave the appliance unattended when it is on.

- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.

- Avoid flux coming into contact with skin or eyes to prevent irritation.

- Be careful with the fumes produced when soldering.

- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working 

to avoid personal harm.

- Utmost care must be taken with liquid tin waste which can cause burns.

- This appliance can be used by children over the age of eight and also persons with reduced physical, 

sensory or mental capabilities or lack of experience provided that they have been given adequate 
supervision or instruction concerning use of the appliance and understand the hazards involved. 
Children must not play with the appliance.

- Maintenance must not be carried out by children unless supervised.

  It is imperative to follow safety guidelines to prevent electric 
  shock, injury, fire or explosion. 

 

Specifications

HD
Heavy Duty Station 

Ref.: 

HDE-9D

 100V 50/60Hz. Input fuse: 4A. Output: 42V.

Ref.: 

HDE-1D

 120V  50/60Hz. Input fuse: 4A. Output: 42V. 

Ref.: 

HDE-2D

 230V 50/60Hz. Input fuse: 2A. Output: 42V. 

 
- Output Peak Power: 

   250W  

- Temperature Range: 

   90 - 500 °C / 190 - 932 °F 

- Idle Temp. Stability (still air): 

   ±1.5ºC / ±3ºF (Meets and exceed IPC J-STD-001F)

- Temp Accuracy:                                 ±3%  (using reference cartridge) 
- Temp Adjustment:                              ±50ºC / ±90ºF Through station menu setting  
- Tip to Ground Voltage/Resitance:      Meets and exceed 
   

    ANSI/ESD S20.20-2014     IPC J-STD-001F

- Ambient Operating Temp.: 

    10 - 50 ºC / 50 - 122 ºF

- Connections: 

    USB-A / USB-B / Peripherals connectors

   

    RJ12 connector for Robot

- Control Unit Dimensions: 

    232 x 148 x 120 mm / 9.13 x 5.83 x 4.72 in

- Total Net Weight: 

 

  5.37 kg / 11.84 lb

- Total Package Dimension / Weight:   368 x 368 x 195 mm / 6.19 kg
  (L x W x H)                                         14.49 x 14.49 x 7.68 in / 13.65 lb

Complies with CE standards.
ESD safe.

40 mm

50 mm

60 mm

80 mm

100 mm

130 mm

130 mm

para manuales - color gris

200 mm

300 mm

Summary of Contents for HDE-9D

Page 1: ...HD Heavy Duty Station INSTRUCTION MANUAL ...

Page 2: ...wer Cord 1 unit Ref 0024077 100V 0023717 120V 0024080 230V Stand Cable 1 unit Ref 0024227 ESD Tip Cleaner 1 unit Ref CL8499 Sponge 1 unit Ref S0354 Cartridge Holder 1 unit Ref SCH A Packing List The following items are included This manual corresponds to the following references HDE 9D 100V HDE 1D 120V HDE 2D 230V ...

Page 3: ...connector for joining modules and pedals USB B connector Equipotential connection Power Socket HD Purpose Handle Ref T470 FA C470 Cartridges Required but not included Stand Cable Ref 0024227 Connections 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm ...

Page 4: ...E A Nitrogen Flow Regulator Ref MNE A Pedal Ref P 005 Pedal Ref P 005 Use this foot switch to enable disable a module or make the tool enter exit Sleep mode If you do not have a module you can link up the P 305 Pedal Kit to the tool port Features USB A connector 2 8 Color TFT screen Tilt the display for easy reading Main Switch ...

Page 5: ... PIN 0105 Change Port Displayed if Temperature Levels are Activated Station Tools Counters Reset Language Peripherals Set the station parameters Set the tool parameters Consult modify the links of the peripherals connected to the station with the port they are connected to Display the hours worked in each cycle It is possible to choose the language from a list Allows you to carry out an overall st...

Page 6: ...n soldering Ceramic Chip components like MLCC this new and unique feature allows controlling the heating ramp up rate of the tool to gradually increase the temperature of the component through all the phases of the soldering process Up to 25 fully configurable soldering profiles can be stored USB flash drive is connected Station is controlled by a PC Station is controlled by a robot System notificati...

Page 7: ...nfigurations for later uses Analyze the soldering graphics of the stations on your PC and export them 1 Download the JBC Software Manager and the user manual from jbcnet solutions 2 Connect the stations via USB B connector and the PC will automatically detect them 3 The notification will be displayed on the station any JBC station USB Hub JBC Manager software 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm ...

Page 8: ...m Our revolutionary technology is able to recover tip temperature extremely quickly It means the user can work at a lower temperature and improve the quality of soldering The tip temperature is further reduced thanks to the Sleep and Hibernation modes which increase up to 5 times the life of the tip 3 Hibernation 1 Work 2 Sleep When the tool is lifted from the stand the tip will heat up to the sel...

Page 9: ...e mark 9 Stand Once the cartridge is properly inserted we recommend tightening the screw to prevent it turning Important It is essential to insert the cartridges as far as the mark for a proper connection 3 Fixing Mark 1 Removing 2 Inserting Screw Changing Cartridges 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm ...

Page 10: ...ing on your handle model Sealing Plug Replacement Before replacing the sealing plug unplug the power supply and make sure the device is not hot Note The chamfered side has to be positioned towards the handle 2 Mounting Position 3 Inserting Sealing Plug 1 Removing Sealing Plug Sealing Plug Handle Push the sealing plug inside the handle until the sealing plug and handle edges are aligned Enter not d...

Page 11: ... 9ft cable Ref T470 MC 3m 9 8ft cable Foam Tri lobed HD Iron with anti slip grip Ref T470 ZA 1 5m 4 9ft cable For better handling of the tool Nitrogen HD Iron with anti slip grip Ref T470 NA 1 5m 4 9ft cable Nozzles Ref B6193 B6194 B6195 The MNE Nitrogen Flow Regulator is required Only used with a DN SE stand Nitrogen feed HD Thermal Tweezers Ref HT470 A Only used with two HDE D control units and ...

Page 12: ...hen using the brass wool ESD Tip Wiper Ref CL0240 A temperature resistant receptacle lets the operator remove excess solder by gentle tapping or wiping Antisplash Membrane Ref 0017574 Prevents splashing to maintain the work area clean Non slip base Sponge Ref S0354 No need to hold the base while cleaning tips The least harmful cleaning method Keep the sponge damp with distilled water when working ...

Page 13: ... cloth to clean the casing and the tool Alcohol can only be used to clean the metal parts Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables and tube...

Page 14: ...ls Heat can cause inflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over...

Page 15: ...mp Adjustment 50ºC 90ºF Through station menu setting Tip to Ground Voltage Resitance Meets and exceed ANSI ESD S20 20 2014 IPC J STD 001F Ambient Operating Temp 10 50 ºC 50 122 ºF Connections USB A USB B Peripherals connectors RJ12 connector for Robot Control Unit Dimensions 232 x 148 x 120 mm 9 13 x 5 83 x 4 72 in Total Net Weight 5 37 kg 11 84 lb Total Package Dimension Weight 368 x 368 x 195 mm...

Page 16: ...rranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased Get 1 extra year JBC warranty by registering here https www jbctools com productregistration within 30 days of purchase...

Reviews: