Summary of Contents for PHB-1A

Page 1: ...31 Deutsch 21 Espa ol 11 Convection Preheater Ref PHB A English 2 Page INSTRUCTION MANUAL www jbctools com...

Page 2: ...Power Cord 1 unit Ref 0009417 100V 120V 0009401 230V Thermocouple 1 unit Ref PH218 Kapton Tape 1 unit Ref PH217 Manual 1 unit Ref 0016286 Ref PHB A Convection Preheater Convection Preheater 1 unit Re...

Page 3: ...s Power socket Power Fixing brackets for PHB SA Convection Preheater Support Heater Unit Console Control Unit Start Stop Auxiliary Thermocouple Type K Input Thermocouple Type K Ref PH218 USB B connect...

Page 4: ...petitive jobs we recommend running profiles without the Thermocouple TC Once any profile has been run to the end the system has all the process data which you can save Once it is saved you can run thi...

Page 5: ...s reached the Heater Unit will stop the process and a warning message will be shown 3 IPC does not recommend exceeding ramp up rates over 3 4 C sec 5 7 F sec so as to reduce the risk of thermal stress...

Page 6: ...6 Display Control...

Page 7: ...7 www jbctools com...

Page 8: ...Alcohol can only be used to clean the metal parts Clean periodically Only if it is absolutely necessary and if cleaning with IPA is not enough it is recommended to use a scraper to remove dirt in the...

Page 9: ...can cause inflamable products to ignite even when out of sight Be careful with the remains of liquid tin In contact with skin it can cause burns Avoid flux coming into contact with skin or eyes to pr...

Page 10: ...6 x 41 mm 16 7 x 17 6 x 1 6 in Maximum Power 1800W 1800W 1400W Heating Area 180 x 277 mm 7 1 x 10 9 in 1 zone 360 x 277 mm 14 2 x 10 9 in 2 zones Temperature Range 50 250 C 120 482 F Temperature Measu...

Page 11: ...Precalentador Ref PHB A 11 www jbctools com...

Page 12: ...0009401 230V Thermocouple Termopar Tipo K 1 unidad Ref PH218 Kapton Tape Cinta Kapton 1 unidad Ref PH217 Manual 1 unidad Ref 0016286 Convection Preheater Precalentador 1 unidad Ref PHB 1A 120V PHB 2A...

Page 13: ...oras Toma de Red Interruptor general Fijadores para el soporte PHB SA Unidad de Control Bot n Inicio paro Conector para Termopar auxiliar Tipo K Termopar Tipo K Ref PH218 Conector USB B a PC Actualice...

Page 14: ...forme y progresivo Estos perfiles no son modificables pero pueden ser usados como plantilla para crear sus propios perfiles User Profiles Perfiles de Usuario Puede crear sus propios perfiles a partir...

Page 15: ...settings Si la temperatura llega a la establecida se interrumpir el proceso y mostrar un warning 3 IPC no recomienda exceder tasas de rampas por encima de los 3 4 C seg 5 7 F seg con el fin de reduci...

Page 16: ...Pantallas de control 16...

Page 17: ...17 www jbctools com...

Page 18: ...ce alcohol para las partes met licas Limpie peri dicamente Solo cuando sea absolutamente necesario y si la limpieza con IPA no es suficiente se recomiendaelusodeunarasquetaparalimpiar la suciedad adhe...

Page 19: ...o En contacto con la piel puede causar quemaduras Evite el contacto del Flux con la piel o los ojos para prevenir la irritaci n Tenga cuidado con el humo producido al trabajar Mantenga su lugar de tra...

Page 20: ...ora 426 x 446 x 41 mm 16 7 x 17 6 x 1 6 in Potencia m xima 1800W 1800W 1400W rea calefactora 180 x 277 mm 7 1 x 10 9 in 1 zona 360 x 277 mm 14 2 x 10 9 in 2 zonas Rango de temperatura 50 250 C 120 482...

Page 21: ...Unterheizung Ref PHB A 21 www jbctools com...

Page 22: ...120V 0009401 230V Thermocouple Thermoelement 1 St ck Ref PH218 Kapton Tape Kaptonband 1 St ck Ref PH217 Handbuch 1 St ck Ref 0016286 Convection Preheater Unterheizung 1 St ck Ref PHB 1A 120V PHB 2A 2...

Page 23: ...halter Befestigungs elemente f r PHB SA Steuereinheit Start Stopp Eingang f r Hilfsthermoelement Typ K USB B Anschluss zum PC Zum aktualisieren der Steuereinheits software Heater Unit Vorheizger t Con...

Page 24: ...nnen nicht ge ndert werden aber sie k nnen als Vorlage verwendet werden um eigene Profile zu erstellen JBCset A 2 Stufen JBCset B 3 Stufen JBCset C 4 Stufen F r sich wiederholende Arbeiten empfehlen w...

Page 25: ...Settings ausw hlen Wenn die gew hlte Temperatur erreicht ist wird das IR Vorheiz System den Prozess stoppen und eine Warnmeldung angezeigen Kapton Band um das Thermoelement TC auf der Leiterplatte zu...

Page 26: ...Menu Steuerung 26...

Page 27: ...27 www jbctools com...

Page 28: ...ng der Metallteile benutzt werden Regelm ig reinigen Nur wenn es absolut notwendig ist und wenn die Reinigung mit Isopropanol IPA nicht ausreicht k nnen Sie zum Beseitigen von Schmutzresten auf der Sc...

Page 29: ...brennungen f hren Ein als ohne R ckst nde eingestuftes Flussmittel verwenden und die Ber hrung mit Haut oder Augen vermeiden um Reizung zu vermeiden Sich vor dem beim L ten entstehenden Rauch in Acht...

Page 30: ...rheizger t 426 x 446 x 41 mm 16 7 x 17 6 x 1 6 in Maximale Leistung 1800W 1800W 1400W Heizfl che 180 x 277 mm 7 1 x 10 9 in 1 zone 360 x 277 mm 14 2 x 10 9 in 2 zonen Temperaturbereich 50 250 C 120 48...

Page 31: ...Ref PHB A 31 www jbctools com...

Page 32: ...wer Cord 1 Ref 0009417 100V 120V 0009401 230V Thermocouple 1 Ref PH218 Kapton Tape 1 Ref PH217 1 Ref 0016286 Convection Preheater 1 Ref PHB 1A 120V PHB 2A 230V PHB 9A 100V 32 Ref PHB A Convection Preh...

Page 33: ...Ref P 005 PHB SA Heater Unit Console K K Ref PH218 USB B A B 33 www jbctools com...

Page 34: ...Temperature profiles TC JBC 3 JBC 10 JBC A 2 JBC B 3 JBC C 4 TC TC JBCset profiles JBC 3 A B C 2 3 4 User Profiles JBC FR4 1 6mm 2 FR4 2 2mm 6 FR4 1 6mm 6 Power Mode TC PHB SA 28mm 34...

Page 35: ...TC 1 TC 2 IR 3 IPC 3 4 C 5 12 F IPC 1957 TC 35 www jbctools com...

Page 36: ...36...

Page 37: ...37 www jbctools com...

Page 38: ...PHB A IPA JBC JBC 38...

Page 39: ...39 www jbctools com...

Page 40: ...60Hz 15A PHB 2A 230V 230V 50 60Hz 10A PHB 9A 100V 100V 50 60Hz 15A 7 kg 15 4 lb 426 x 446 x 41 mm 16 7 x 17 6 x 1 6 in 1800W 1800W 1400W 180 x 277 mm 7 1 x 10 9 in 1 360 x 277 mm 14 2 x 10 9 in 2 50 2...

Page 41: ...41 Notes www jbctools com...

Page 42: ...42 Exploded View Despiece Explosionszeichnung...

Page 43: ...43 www jbctools com...

Page 44: ...defectuosas y mano de obra La garant a no cubre el desgaste del producto por uso o mal uso Para que esta garant a sea v lida el equipo debe ser devuelto a portes pagados al distribuidor donde se comp...