6
For repetitive jobs
we recommend
running profiles without the Thermocouple (TC). In order to do
so, the
Teach profile
mode has to be executed before running any profile. It can be executed from
the
Work mode
menu if the
Profiles
mode is selected. Once the profile has been run to the end, the
system has all the process data which you can save.
Once it is saved, you can run this profile without connecting the Thermocouple (TC). The heating
process will be the same as long as the same working conditions are respected.
The profiles which already have the data from the
Teach profile
are marked with this symbol
These profiles can be run either with or without the Thermocouples. It can be chosen from the
Profiles
mode work screen:
Teach profile
Select
Profile mode
from the
Work mode
menu. In this mode the heater unit regulates the
temperature of the TC1 thermocouple according to the selected profile as long as the other TCs do
not reach the control/protection temperature limit.
Profiles mode
14:15
20
º
C
TC1
Stop
20
º
C
TC2
PROFILE1
200
100
20
º
C
TC3
20
º
C
TC4
Summary of Contents for PHBE-A
Page 1: ...Convection Preheater Ref PHBE A INSTRUCTION MANUAL www jbctools com...
Page 14: ...Notes 14...
Page 15: ...15 www jbctools com...