background image

PHSE-K

Small Preheater Set

INSTRUCTION MANUAL

www.jbctools.com

Summary of Contents for PHSE-K

Page 1: ...PHSE K Small Preheater Set INSTRUCTION MANUAL www jbctools com ...

Page 2: ...tems are included Power Cord 1 unit Ref 0023715 120V 0023714 230V 0024092 100V Thermocouple 2 unit Ref PH218 Kapton Tape 1 unit Ref PH217 Manual 1 unit Ref 0021330 Small PCB Support 1 unit Ref PHS SA Small Preheater Unit 1 unit RJ45 Cable 1 unit Ref 0019914 ...

Page 3: ...ackets for Small PCB Support Heater Unit Console 2 8 Color TFT Screen Start Stop USB B Connector Zone B Zone A RJ45 Connector to Preheater Unit USB A Connector Foot for Vertical Set Up Button for Foot Folding and Unfolding USB B Connector RJ45 Connector to Console RJ12 Connector to Robot Thermocouple Connectors x4 Type K Support www jbctools com ...

Page 4: ...orts 3 Place the guides the rubber cups and adjust the sliding clamp knobs again 28mm 50mm 70mm Unscrew these knobs to place the support in the lowest level It allows adjustment for 3 heights between the PCB and the Heating Area of the Preheater Low level High level Medium level Height Adjustment Use the fixing brackets to place the support in the medium and the high level ...

Page 5: ...Replacement The support lets you replace PCBs of the same batch fast and easily Use the sliding guides to change the PCBs Removing the PCB Place large PCBs on the 4 rubber caps Reworking large PCBs Adjustable slot clamps for switching PCBs Placing another PCB Position it and tighten the sliding guide knobs www jbctools com ...

Page 6: ...SB flash drive is connected Station is controlled by a PC Station is controlled by a robot Station software update Press INFO to start the process Warning Press INFO for failure description Error Press INFO for failure description the type of error and how to proceed System notifications Status Bar Original PIN 0105 General Work mode Profile editor Reset Graphics Files Available languages English ...

Page 7: ...titute for Printed Circuits and is committed to becoming the most recognized international industry association for the electronics manufacturing industry Fix with Kapton Tape Protection Thermocouple Setting Thermocouples Function Select Thermocouples from the Work mode menu to set them up The thermocouples TC can work in three diferent ways depending on what is needed Control the unit mantains th...

Page 8: ...ermocouple Current Temp Select Temp mode from the Work mode menu In this mode the heater unit maintains the selected temperature for the TC1 thermocouple as long as the other TC s do not reach the control protection temperature limit TC1 Current and Selected Temperature Temperature Mode 14 15 20º C Power 45 TC1 45ºC Selected 120ºC TC2 P 100ºC 20º C TC3 P 100ºC 20º C TC4 P 100ºC 14 15 20º C Power 4...

Page 9: ...ong as the same working conditions are respected The profiles which already have the data from the Teach profile are marked with this symbol These profiles can be run either with or without the Thermocouples It can be chosen from the Profiles mode work screen Teach Profile Select Profile Mode from the Work Mode Menu In this mode the heater unit regulates the temperature of the TC1 thermocouple acc...

Page 10: ... edit as many as 25 profiles of temperature Menu Options JBC Set Profiles There are 3 profiles predefined by JBC A B and C The difference between them is the number of steps 2 3 or 4 The thicker your PCB is and the more layers it contains the more steps are needed to obtain a gradual warming These profiles are not modifiable but can be used as a template to create your own profiles JBC A 2 steps J...

Page 11: ...en Power and Temperature USB flash drive is connected Station is controlled by a PC Station is controlled by a robot System Notifications Station software update Press INFO to start the process Warning Press INFO for failure description Error Press INFO for failure description the type of error and how to proceed The following icons will be displayed on the screen s status bar Graphics 11 www jbcto...

Page 12: ...wnload the JBC Update File from www jbctools com software html and save it on a USB flash drive Preferably one with no other files 2 Insert the USB flash drive to the console The icon is diplayed while updating Files Working with Pedal Press the pedal to start heating and press again to stop as if it was the button on the console Once the Work Mode is set the Heater Unit can work without the conso...

Page 13: ...cleaning Alcohol can only be used to clean the metal parts Only if it is absolutely necessary and if cleaning with isopropyl alcohol IPA is not enough it is recommended to use a scraper to remove dirt in the glass area Replace any defective or damaged parts Use original JBC spare parts only Repairs should only be performed by a JBC authorized technical service 13 www jbctools com ...

Page 14: ...n cause inflamable products to ignite even when out of sight Be careful with the remains of liquid tin In contact with skin it can cause burns Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the smoke produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm This appliance can...

Page 15: ... Set Temperature Profiles 3 profiles 2 3 or 4 steps User Profiles 20 up to 6 steps for each Maximum Work Time 600 min or indefinite Dimensions Weight 195 x 288 x 41 5 mm 2 8 kg L x W x H 7 68 x 11 34 x 1 63 in 6 2 lb Small PCB Support PHS SA Weight 2 kg 4 4 lb Dimensions Low Position 267 x 259 x 75 mm L x W x H 10 5 x 10 2 x 3 in Dimensions High Position 267 x 259 x 96 mm L x W x H 10 5 x 10 2 x 3...

Page 16: ...r warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased Get 1 extra year JBC warranty by registering here https www jbctools com productregistration within 30 days of purc...

Reviews: