9
· Add point
· Delete point
· Load profile
· Save profile
· Exit
Data for
these points
Profile name
Profile editor
The
Profile editor
can be opened from the main menu or from the
Profiles
mode work
screen by pressing the ‘OK’ button.
In this mode you can
edit
as many as 25 profiles of temperature.
Menu
Options
Profile
editor
JBC set profiles
There are 3 profiles predefined by JBC: A, B and C. The difference between them is the number of
steps: 2, 3 or 4. The thicker your PCB is and the more layers it contains, the more steps are needed
to obtain a gradual warming.
These profiles are not modifiable but can be used as a template to create your own profiles.
JBC-A
2 steps
JBC-B
3 steps
JBC-C
4 steps
PCB reference
specifications:
FR4 1,6mm thick
and 2 layers.
FR4 2,2mm thick
and 6 layers.
FR4 1,6mm thick
and 6 layers.
Profiles set using the low position of the PHS-SA Support (28 mm in height between the PCB and the heating area).
14:15
5m 00s
150
º
C
PROFILE1
200
100
0
60
120
180
240
300
Point
2/4
Temp
Time
2m 00s
www.jbctools.com
Summary of Contents for PHSE-KA
Page 1: ...IR Preheater Set Ref PHSE KA INSTRUCTION MANUAL www jbctools com...
Page 16: ...16 Notes...
Page 17: ...17 www jbctools com...
Page 18: ...18 Exploded View...
Page 19: ...19 www jbctools com...