Temp
º
C
Air %
Time to stop 45 seconds
Power 70%
400 85
400
º
C Select
Temp
º
C
º
C
Program 8
380
Air
100%
Time 125s.
12
13
Operation with JT station
Process Control
3. Releasing
1. Placing
2. Heating
Position the suction cup.
Push the button for hot air
heating. The solder melts.
The component lifts off
automatically.
Access Menu (pess key 2 seconds) & Confirm Selection
Selected temperature
Current temperature
% Instant power supplied
to heater
You can switch between operating modes (Manual Mode / Profile Mode) by pressing the “increa-
se” and “decrease” keys simultaneously for 2 seconds. (Only when mode profiles is ON)
Manual mode
Decrease program
number
Increase program
number
Selected program
Current temperature
Selected flow
Graph of selected
program
Remaining time
Program mode
Program Options
Edit Program
This option allows you to edit or create a program.
First , you must select the program to edit and then modify the points that make up the program.
Each program is composed of 9 points, each point consisting of 3 parameters:
1. Time (seconds)
2. Temperature (°C / °F)
3. Flow rate (%)
You can delete the last point of the program by selecting “-----” in the time parameter.
It should be taken into account that the regulation range permitted by the station is 150-450°C,
whereby it is not possible to create temperature ramps between room temperature (Toff) and
150°C.
The station can store up to 25 temperature programs.
The first three programs are edited by JBC as an example.
Copy Program
This option allows you to copy a program.
You must select the program source and the program destination (where it will be copied).
Delete Program
This option will allow you to delete a previously selected program.
www.jbctools.com